S'abonner

Posterior implant tilt as an alternative to sinus elevation in full-arch maxillary rehabilitation: A comparative finite element analysis - 25/09/26

Doi : 10.1016/j.jormas.2026.103006 
Elif Ezgi Oğuz a , Aras Erdil b, ⁎ , Mehmet İğneci c
a Department of Prosthodontics, Faculty of Dentistry, Altınbaş University, İstanbul, Turkey 
b Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Uşak University, Uşak, Turkey 
c Clinic of Oral and Maxillofacial Surgery, Uşak Oral and Dental Health Center, TR Ministry of Health, Uşak, Turkey 

⁎ Corresponding author.

Abstract

Introduction

This finite element analysis study aimed to compare the stress distributions in cortical and trabecular bone, implants, abutments, and prosthetic components under anterior and posterior loading in three different implant configurations, including maxillary sinus grafting, in a completely edentulous and posteriorly atrophic maxilla. The study specifically focused on identifying the differences between a prosthetic design with a distal cantilever after maxillary sinus lift (Model 3) and configurations without a cantilever, featuring posteriorly angled implants with different exit points (Models 1 and 2).

Materials & methods

An atrophic maxillary model was reconstructed from computed tomography images obtained from a publicly available online database. Each study model utilized six Straumann BL Roxolid implants, with a screw-retained cobalt-chromium alloy prosthetic substructure. In each model, the implants were placed vertically anterior to the maxillary sinus; Model 1 featured a distally angled implant with its exit point at the second molar, Model 2 included a tuberoid implant connected to the prosthetic substructure with a distal extension, and Model 3 featured an axial implant placed at the level of the first molar after sinus grafting. All models were subjected to a foodstuff-style force of 100 N in the anterior and posterior regions. Maximum principal stress (σ_max), minimum principal stress (σ_min), and von Mises stress were recorded in the implant, periimplant bone, and prosthetic components.

Results

Under anterior loading, Model 3 produced the highest peak stresses in the framework (33.218 MPa), implant (15.444 MPa), abutment (21.247 MPa), and cortical bone (maximum principal stress, 3.874 MPa; minimum principal stress, -4.017 MPa). Under molar loading, Model 3 produced the highest framework, implant, and abutment stresses (54.844, 33.259, and 49.019 MPa, respectively) but lower posterior cortical stresses (maximum principal stress, 3.319 MPa; minimum principal stress, -6.453 MPa) than Model 1 (6.524 and -13.243 MPa) and Model 2 (7.641 and -13.327 MPa).

Discussion

No configuration minimized stress in every structure. The graftless configurations reduced selected prosthetic stresses but transferred greater demand to posterior cortical bone, whereas the sinus-grafted configuration reduced posterior cortical stress while increasing mechanical demand in the cantilevered prosthetic complex. Treatment planning should therefore consider the distribution of biomechanical demand across the entire bone-implant-prosthesis system rather than a single peak value.

Le texte complet de cet article est disponible en PDF.

Keywords : Finite element analysis, Dental implants, Atrophic maxilla


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 127 - N° 6

Article 103006- décembre 2026 Retour au numéro
Article précédent Article précédent
  • Association between the mandibular cortical index on panoramic radiographs and mandibular condylar alterations after osteotomy
  • Hiroshi Yamamoto, Hirotaka Muraoka, Mami Shimizu, Erika Iwai, Hajime Noda, Yoshimasa Ishii
| Article suivant Article suivant
  • Three-dimensional voxel-based evaluation of surgical accuracy and one-year stability after segmented Le Fort I osteotomy for anterior open bite correction
  • Oliver da Costa Senior, Eman Shaheen, Reinhilde Jacobs, Constantinus Politis, Kasper Stokbro

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.