S'abonner

Volar Rim Morphology and Plate Congruence in Fragment-Specific Distal Radius Fixation - 05/10/26

Doi : 10.1016/j.hansur.2026.102813 
Jean-Baptiste de Villeneuve Bargemon a, b, c, ⁎ , Lucas Audiffret a, b, c, Clément Prenaud d, Romain Ambrosino a, b, Camille Brenac a, b, c
a Department of Orthopaedic and Trauma Surgery, AP-HM, Hôpital de la Timone, Marseille, France 
b Institute of Movement and Locomotor System (IML), Sainte-Marguerite Hospital (University), 270 Boulevard Sainte Marguerite, Marseille, France 
c Wrist and Hand Academy for Research in the Mediterranean (WHARM) 
d Hand and Wrist Surgery Unit, Polyclinique Bordeaux Nord Aquitaine, Bordeaux, France 

⁎ Corresponding author.
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Monday 05 October 2026

Abstract

Background

Fragment-specific fixation of distal radius fractures often requires implants positioned at or beyond the watershed line, which may increase the risk of flexor ultrasound-detected flexor tendon abnormalities. However, tendon conflict may depend not only on plate position but also on how the implant adapts to individual volar rim morphology.

This study assessed whether volar rim morphology, classified according to the Dolomites concept, was associated with plate application and ultrasound-detected flexor tendon abnormalities after fragment-specific fixation. We hypothesized that Dolomites volar rim morphology would be associated with plate-to-bone application and with ultrasound-detected flexor tendon abnormalities.

Patients and Methods

A single-centre prospective cohort study included adult patients treated surgically for distal radius fractures requiring fragment-specific fixation at or beyond the watershed line. At 6 months, postoperative CT was used to classify volar rim morphology as Dolomites type 1 or type 2 and to assess plate application. Distal plate-to-bone incongruence was defined as a plate-to-bone distance greater than 2 mm at the most palmar point of the distal radius. Systematic ultrasound was performed to identify flexor tendon abnormalities. Associations between volar rim morphology, plate application, and ultrasound-detected flexor tendon abnormalities were analyzed overall and by plate type.

Results

Of 152 initially included patients, 123 were available for analysis. Dolomites type 1 anatomy was present in 95 patients (77.2%) and type 2 in 28 patients (22.8%). Overall, distal plate-to-bone incongruence was observed in 30 cases (24.4%) and ultrasound-detected flexor tendon abnormalities in 43 cases (35.0%). Dolomites anatomy was not significantly associated with distal plate-to-bone incongruence when all plate types were analyzed together: 26 of 95 type 1 cases (27.4%) versus 4 of 28 type 2 cases (14.3%; p = 0.212). However, among hook plates, distal plate-to-bone incongruence was significantly more frequent in type 1 than in type 2 anatomy: 11 of 22 cases (50.0%) versus 2 of 23 cases (8.7%; p = 0.003). Distal plate-to-bone incongruence was strongly associated with ultrasound-detected flexor tendon abnormalities, which occurred in 28 of 30 incongruent plates (93.3%) compared with 15 of 93 congruent plates (16.1%; p < 0.001).

Discussion

Ultrasound-detected flexor tendon abnormalities were substantially more frequent in cases of distal plate-to-bone incongruence. Although Dolomites morphology was not associated with distal plate-to-bone congruence in the overall cohort, exploratory subgroup analysis suggested a potential association between volar rim morphology and hook plate congruence. Further validation is required before this classification can be incorporated into routine implant selection.

Level of evidence

III; prospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal radius fracture, Volar rim, Ultrasonography, Flexor tendon, Fragment-specific fixation, Dolomites concept



© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.