Periprosthetic tibial fracture in robotic-assisted versus conventional medial UKA: in vitro testing and finite element analysis of baseplate footprint - 14/10/26

Doi : 10.1016/j.otsr.2026.104919 
Yeseop Park a, Michael Redondo a, Nirav Mungalpara a, Crystal Lin a, Hristo Piponov b, Lalit Puri b, Farid Amirouche a, c, ⁎
a Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, IL, United States of America 
b of Orthopaedic Surgery, Endeavor Health, an Affiliate of Pritzker College of Medicine, University of Chicago, Skokie, IL, United States of America 
c Department of Orthopaedic Surgery, Institute of Orthopaedics and Spine, Endeavor Health (Former Northshore University Health System), an Affiliate of Pritzker School of Medicine, University of Chicago, Skokie, IL, United States of America 

⁎ Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 14 October 2026

Abstract

Background

Periprosthetic tibial fracture after unicompartmental knee arthroplasty (UKA) is uncommon but clinically important. Although robotic-assisted UKA may improve the precision of bone preparation and component positioning, whether these technical differences influence fracture resistance or fracture morphology remains unclear. This in vitro study examined whether robotic-assisted medial UKA alters axial load-to-failure compared with conventional UKA, whether fracture morphology differs between the two techniques, and whether implant base footprint influences fracture behavior in complementary finite element (FE) simulations.

Hypothesis

Robotic-assisted medial UKA would alter tibial fracture behavior compared with conventional UKA, as reflected by differences in fracture resistance and fracture morphology.

Methods

Fourteen fresh-frozen cadaveric specimens underwent medial UKA using either conventional instrumentation (n = 7) or a robotic-assisted workflow (n = 7). After implantation, the tibiae were isolated and subjected to monotonic axial compression at 0.5 mm/s until macroscopic periprosthetic fracture occurred. Load-to-failure, failure load normalized to body weight, and fracture morphology were evaluated. Complementary FE models incorporating implant baseplate sizes 8 and 10 were used to compare load-displacement behavior and crack propagation.

Results

Axial load-to-failure did not differ significantly between conventional and robotic-assisted UKA (3712.4 ± 1746.2 N vs. 3988.3 ± 1534.5 N, p = 0.90). Failure load normalized to body weight was also not significantly different between groups (524.42 ± 262.60% vs. 647.24 ± 212.54%, p = 0.71). Different predominant fracture patterns were observed despite similar fracture resistance. Robotic-assisted specimens primarily demonstrated metaphyseal depression-type fractures, whereas fractures in conventional specimens more frequently propagated toward the meta-diaphyseal region. In the FE simulations, peak loads were 3755.36 N for the size-8 baseplate model and 4005.36 N for the size-10 baseplate model, both within the variability observed experimentally, with differences in crack propagation between implant baseplate sizes.

Discussion

Robotic-assisted medial UKA did not significantly alter axial fracture resistance compared with conventional UKA, although different predominant fracture morphologies were observed between techniques. Complementary FE analysis showed that implant base footprint influenced simulated load-displacement behavior and crack propagation, suggesting that implant footprint may contribute mechanically to differences in fracture behavior after medial UKA.

Level of evidence

V; biomechanical cadaveric and in silico investigation.

Le texte complet de cet article est disponible en PDF.

Keywords : Uni-compartmental knee arthroplasty (UKA), Periprosthetic tibial fracture, Robotic-assisted UKA, Biomechanics, Finite element analysis (FEA), Load-to-failure


Plan


© 2026  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.