S'abonner

Accuracy of hard tissue predictions in mono- and bimaxillary orthognathic surgery using 3D virtual surgical planning - 17/10/26

Doi : 10.1016/j.jormas.2026.103031 
Sacha André Decho a, Konrad Tolksdorf a, Christoph-Ludwig Hennig b, Stefan Schultze-Mosgau a, Martin Fischer a, ⁎
a Department of Oral and Cranio-Maxillofacial-Surgery/Plastic Surgery, Jena University Hospital, Friedrich Schiller University of Jena, Jena, Germany 
b Department of Orthodontics, Jena University Hospital, Friedrich Schiller University of Jena, Jena, Germany 

⁎ Corresponding author at: Department of Oral and Cranio-Maxillofacial-Surgery/Plastic Surgery, Jena University Hospital, Friedrich Schiller University of Jena, Am Klinikum 1, Jena 07749, Germany. Department of Oral and Cranio-Maxillofacial-Surgery/Plastic Surgery Jena University Hospital Friedrich Schiller University of Jena Am Klinikum 1 Jena 07749 Germany

Abstract

Background

Three-dimensional virtual planning is an established method in orthognathic surgery. While numerous studies support its accuracy and precision, considerable variability in its extent has been reported.

Aim of the study

This study assessed whether postoperative cephalometric outcomes corresponded to planned values within predefined clinically acceptable limits.

Material and methods

This retrospective cohort study included 53 patients with dentofacial deformities who underwent bilateral sagittal split osteotomy with ( n =29) or without Le Fort I osteotomy ( n =24). The dataset comprised preoperative computed tomography scans of the skull and pre- and postoperative lateral cephalometric radiographs. Initially, two- and three-dimensional preoperative cephalometric analyses were compared to quantify measurement errors. Subsequently, angular parameters planned during three-dimensional virtual surgical planning were compared with those obtained postoperatively via two-dimensional cephalometric analysis. Equivalence was assessed using predefined clinical limits of ±2° with two one-sided tests.

Results

Preoperatively, no statistically significant angular deviations between 2D and 3D cephalometry were identified ( p > 0.05). Postoperatively, five out of seven angular parameters met the criterion for equivalence, with mean deviations within ±2°. For MnP-NS and MxP-MnP, mean deviations exceeding 2° were shown (2.054 and 2.015, respectively).

Conclusion

Virtual surgery planning demonstrated clinically acceptable accuracy for maxillary positioning in midsagittal plane. However, mandibular vertical repositioning did not meet predefined equivalence criteria in the selected angular parameters. For unbiased postoperative evaluation of mandibular positioning, lateral cephalometric radiographs should be obtained after resolution of early confounding factors and represent a cost-effective, low-radiation alternative to three-dimensional imaging for sagittal and vertical assessment.

Le texte complet de cet article est disponible en PDF.

Keywords : Orthognathic surgery, Cephalometry, Patient-specific modeling


Plan


© 2026  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 127 - N° 6

Article 103031- décembre 2026 Retour au numéro
Article précédent Article précédent
  • Mapping the course of the greater palatine artery using handheld Doppler: a descriptive cross-sectional study
  • Chanchal Dharia, Kirushnavani Vadivelu, Charudatta Naik, Sanjay Joshi, Romi Jain, Tulsi Upadhyay
| Article suivant Article suivant
  • All-in-one digital template-guided apicoectomy and modified socket shield technique for apical-infected aesthetic sites: A technical note
  • Xueqi Guo, Lingqiao Xu, Dongping Lan, Mi Zhou, Zheqing Zhou, Yang Yang, Yi Man

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.