S'abonner

Use of patient-specific instrumentation for hip resurfacing arthroplasty: measurement of accuracy using pre and postoperative CT-scan - 31/10/26

Doi : 10.1016/j.otsr.2026.104934 
Mehdi Hormi-Menard ⁎ , Philippe-Alexandre Faure, Martin Bauters, Ramez Shaker, Julien Girard
 Department of Orthopaedic Surgery, Roger Salengro Hospital, University Hospital of Lille and University of Lille, Place de Verdun, 59037 Lille, France 

⁎ Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 31 October 2026

Abstract

Background

Hip resurfacing arthroplasty (HRA) is a valuable option for the treatment of primary osteoarthritis in young patients. However, the learning curve for femoral component implantation remains long. Few data are dedicated to patient-specific instrumentation (PSI) in this indication, and merely applied to limited study groups using X-rays as tool to assess accuracy of the method. Therefore, we conducted a prospective study assessing the results of PSI for HRA using pre- and postoperative CT scans based aiming to: (1) assess the accuracy of the planned axis in the axial and coronal planes, (2) evaluate if 3D planning could reproduce the native head diameter by a maximum deviation of one implant size (2 mm) from the component ultimately implanted.

Hypothesis

Our hypothesis was that PSI-assisted femoral component implantation would achieve an average accuracy within 5 ° of the planned axis in the axial and coronal planes.

Materials and methods

This prospective study analyzed 49 patients (51 HRA) with complete data from an initial cohort of 50 patients. On pre- and post-operative CT scans, the native caput-collum-diaphyseal (CCD) angle, stem-shaft angle (SSA), femoral anteversion and head diameter were measured. The objectives for the PSI jig were to restore head diameter, femoral anteversion and to implant the femoral component with a planned +5 ° valgus alignment in the coronal plane.

Results

During the surgery, the calcar-guided PSI (inferior jig) was used in 39 cases (76.4%), and the posterior neck-guided PSI (posterior jig) was used in 12 cases (23.6%). No jig failures were observed. Native femoral anteversion averaged 20 ° (range, 15–24) compared to 18.5 ° (range, 10−27 °) postoperatively (p = 0,3). The mean preoperative CCD was 132.5 ° (range, 126–137). The planned SSA was 138 ° (range, 132–143) while the postoperative SSA was 136.5 ° (range, 129–143) (p = 0,1). With accurate positioning being defined as placement within 5 ° of the planned anteversion and SSA, 48 cases (94.1%) achieved the desired femoral component positioning. The mean acetabular cup and femoral head diameters were respectively 58 mm (range, 54–64) and 52 mm (range, 48–58). The native head diameter averaged 51.5 mm (range, 47–57) (p = 0,2).

Discussion

The accuracy of the HRA position was excellent, with more than 94% of cases achieving desired positioning. The maximum difference between the planned and implanted head sizes was 2 mm (1 size), confirming our hypothesis. These findings support the use of this type of PSI for the HRA procedure.

Level of evidence

IV; prospective case series.

Le texte complet de cet article est disponible en PDF.

Keywords : Hip resurfacing, Patient-Specific instrumentation, Hip biomechanics


Plan


© 2026  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.