S'abonner

Evaluation of complex elbow dislocations outside of the triads. Comparison of Monteggia, transolecranon, and transulnar fractures - 10/11/26

Doi : 10.1016/j.otsr.2025.104418 
Camille Bouteille ⁎ , François Saade, Fabio Carminati, Laurent Obert
 CHU de Besancon, Chirurgie Orthopédique et Traumatologique, SOS Mains, Chirurgie Plastique et Reconstructrice, Besançon, France 

⁎ Corresponding author.

Abstract

Introduction

Proximal ulna fractures account for approximately 10% of elbow fractures. Fracture-dislocations present a complex challenge due to their difficulty in analysis and repair. We compared fracture-dislocations according to the Mayo classification. The aim of this study was to compare the clinical and radiological outcomes of Monteggia, transolecranon, and transulnar fracture-dislocations, while excluding terrible triads (Mayo classification). We hypothesized that 46 transulnar fractures involving the basal coronoid would be associated with worse functional results, more advanced arthritis, and higher complication rates.

Material and methods

We reviewed 36 patients who underwent surgery for proximal ulna fracture-dislocations between 2004 and 2019, with a minimum follow-up of 9 months. This was a monocentric retrospective study. We analyzed 9 Monteggia fractures, 13 true olecranon fractures, and 14 ulna fractures with basal coronoid fractures. Clinical parameters (MEPS, QDASH, range of motion), radiological criteria (osteoarthritis, heterotopic ossification, pseudarthrosis, quality of reduction), and complications (stiffness, pseudarthrosis, neurological complications, etc.) were analyzed.

Results

Monteggia fractures had an average MEPS of 87 and an average QDASH of 21.3. The average range of motion for Flexion-Extension was 112 °. Six patients had arthritis at the last follow-up (67%). There were five cases of ossification (56%), one case of pseudarthrosis (11%), and two cases of stiffness (22%). For true olecranon fracture-dislocations, the average MEPS was 74 and the average QDASH was 31. The average range of motion for Flexion-Extension was 92 °. Eleven patients had arthritis at the last follow-up (87.5%). There were eight cases of ossification (62%), two cases of pseudarthrosis (15%), and four cases of stiffness (46%). For ulna fractures with basal coronoid fractures, the average MEPS was 68, and the average QDASH was 41.7. The average range of motion for Flexion-Extension was 85 °. Thirteen patients had arthritis at the last follow-up (93%). There were eight cases of ossification (57%), four cases of pseudarthrosis (29%), and nine cases of stiffness (64%).

Discussion

Ulna fractures with basal coronoid fractures had worse functional outcomes and more complications. Therefore, a strict preoperative assessment of the lesions is necessary for optimal functional recovery.

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Elbow fracture-dislocation, Double plate, Monteggia, True olecranon fractures, Basal coronoid


Plan


© 2025  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 7

Article 104418- février 2026 Retour au numéro
Article précédent Article précédent
  • Utilizing an internal joint stabilizer to ensure post-release elbow stability for patients with severe post-traumatic elbow stiffness: A retrospective cohort study
  • Cheng-You Wang, Yen-Chun Chiu, Chin-Hsien Wu, Chien-Cheng Jasper Liu, Kun-Ling Tsai, I-Ming Jou, Yuan-Kun Tu, Ching-Hou Ma
| Article suivant Article suivant
  • Femoral Morphology and Range of Motion After Eccentric Rotational Acetabular Osteotomy in Males with Hip Dysplasia
  • Hiroto Funahashi, Yusuke Osawa, Yasuhiko Takegami, Hiroaki Ido, Takamune Asamoto, Shiro Imagama

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.