S'abonner

Effect of remodeling on correction of tibia vara using the circular hexapod external fixator - 10/11/26

Doi : 10.1016/j.otsr.2025.104348 
Sherif Galal a, b, Ahmed O. Sabry b, Al-Munqith Al-Abri c, Amr Arafa b, Mohamed Tageldeen Mohamed b, Ahmed Afifi b, ⁎
a Department of Orthopaedic Surgery, Khoula Hospital, Ministry of Health, Muscat, Oman 
b Department of Orthopaedic Surgery, Kasr Al-Ainy Faculty of Medicine, Cairo University, Cairo, Egypt 
c Sultan Qaboos University, Muscat, Oman 

⁎ Corresponding author.

Abstract

Background

We aimed to evaluate if there would be loss of some correction achieved (caused by remodeling) after correcting tibia vara deformity with hexapod circular fixators and if that loss of correction would influence clinical outcomes.

Hypothesis

The hypothesis of the study was that remodeling at the osteotomy site would lead to loss of some correction over time.

Patients and methods

This retrospective study included 18 patients with tibial varus deformity as a sequela of adolescent tibia vara who underwent proximal tibial deformity correction using the Hexapod External Fixator between August 2020 and August 2023. We assessed clinical outcomes using the Limb Deformity-Scoliosis Research Society (LD-SRS) score and radiographic parameters such as Mechanical Axis Deviation (MAD) and Mechanical Axis Angle (MAA) measured preoperatively, post-correction, and at the final follow-up. Statistical analyses were performed to quantify the statistical significance of limb alignment change at final follow-up and to attempt to define a cut-off angle to be achieved at the end of correction that would result in no deviation in limb alignment in the long run.

Results

After a mean follow-up duration of 18.7 mo, there was a significant improvement in both functional and radiographic measures. The mean LD-SRS score improved from 3.4 ± 0.5 preoperatively to 4.6 ± 0.4 at the final follow-up. Radiographic parameters showed notable correction, with the mean MAA improving from 25.1º ± 8.7 (varus alignment) preoperatively to 1.7º ± 2.5 (valgus alignment) at the end of correction, and to 2.4º ± 3.3 (varus alignment) at the final follow-up. Similarly, the mean MAD value improved from 87.4 ± 29.5 mm (medial deviation) preoperatively to 7.3 ± 9.6 mm (medial deviation) at the end of correction, and to 6.1 ± 11.5 mm (lateral deviation) at the final follow-up.

Discussion

When treating adolescents with tibia vara deformity using hexapod fixators, it is advisable to over correct the MAA by 5° (valgus overcorrection) and the MAD by 7–9 mm to counteract the loss of some correction over time caused by the effect of remodeling.

Level of evidence

III; retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Tibia vara, Deformity, External fixation, Hexapod, Taylor spatial frame


Plan


© 2025  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 7

Article 104348- février 2026 Retour au numéro
Article précédent Article précédent
  • Comparison of the OpenPose system and the reference optoelectronic system for gait analysis of lower-limb angular parameters in children
  • Roxane Henry, Sébastien Cordillet, Hélène Rauscent, Isabelle Bonan, Arnaud Huaulmé, Sylvette Marleix, Pierre Jannin, Tiphaine Casy, Philippe Violas
| Article suivant Article suivant
  • Artificial intelligence in hip and knee surgery: a bibliometric analysis of the 50 most cited articles
  • Bernard de Geofroy, Romain Léonard, Margaux Micicoi, Jonggu Shin, Jean-François Gonzalez, Peter K Sculco, Grégoire Micicoi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.