S'abonner

What is the optimal shape and size of a cortical window that least affects bone strength? A biomechanical study - 10/11/26

Doi : 10.1016/j.otsr.2025.104452 
Muhammed Şakir Çalta a, ⁎ , Muhammed Furkan Tosun b, Ethem Burak Oklaz a, Fatma Kübra Erbay Elibol c, Yunus Uslan d, Teyfik Demir d, Şefik Murat Arıkan a
a Department of Orthopaedics and Traumatology, Gazi University Faculty of Medicine,Emniyet Neighborhood, Mevlana Boulevard, No: 29, 06560, Yenimahalle, Ankara, Turkey 
b Department of Orthopaedics and Traumatology, Yenimahalle Training and Research Hospital, Yeni Batı, 2365. Street., 06370 Batıkent/Yenimahalle, Ankara, Turkey 
c Department of Biomedical Engineering, TOBB University of Economics and Technology, Sogutozu Street No: 43, 06560, Sogutozu, Ankara, Turkey 
d Department of Mechanical Engineering, TOBB University of Economics and Technology, Sogutozu Street No: 43, 06560, Sogutozu, Ankara, Turkey 

⁎ Corresponding author.

Abstract

Background

Biopsy and curettage are frequently used in orthopaedic oncology surgeries. However, these procedures reduce bone strength and result in pathological fractures. Therefore, meticulous planning of the size and shape of the cortical window is paramount to preserve bone strength. However, few studies have examined the shape and size of the windows created for biopsy and curettage procedures. The purpose of this study was to evaluate the effect of cortical window shape (rectangular versus elliptical) on bone strength and to evaluate the effect of ellipses with different dimensions on bone strength.

Hypothesis

The hypothesis of this study was that an elliptical cortical window would have a lesser impact on bone strength than a rectangular window, particularly in cases where the length of the ellipse increases while its width decreases.

Materials and methods

Sixty-four synthetic femur models were divided into four groups (n = 8) for compression and torsional tests. Four equal-area cortical windows were created. G1 (rectangular), G2 (elliptical, 1/1.5 ratio), G3 (elliptical, 1/3 ratio), and G4 (elliptical, 1/6 ratio). Compression tests (10 mm/min) were used to assess the maximum load, stiffness, yield load, and fracture energy. Torsion tests (50º/min) were used to measure the maximum torque, stiffness, and work done. Biomechanical performance was compared using load-displacement and torque-angular displacement data.

Results

All bone models were fractured along the cortical window. G3 (elliptical, 511.09 ± 55.07 N) had higher maximum load than G1 (rectangular, 389.18 ± 88.46 N, p = 0.003). The elliptical groups (G2:71.21 N/mm, G3:71.04 N/mm, G4:84.10 N/mm) showed greater compression stiffness than G1 (52.60 N/mm, p ≤ 0.05). G3 had higher yield load (458.72 ± 43.42 N) and work done (2.6 J) than G1 (352.43 ± 91.24 N, 1.78 J, p ≤ 0.05). No significant difference in torsion test results was observed between G3 and G1 (p > 0.05). G2 exhibited lower maximum load, yield load, and work than G3 and G4 (p ≤ 0.003). G4 exhibited higher torque (17.08 Nm) than G2 (11.73 Nm, p = 0.02) and G3 (12.62 Nm, p = 0.018). The torsional stiffness was similar across the elliptical groups.

Discussion

This biomechanical study demonstrated that elliptical cortical windows, especially those with higher length-to-width ratios, outperform rectangular windows in terms of strength under compression and torsional loads. These findings suggest that elliptical cortical windows may provide biomechanical advantages in terms of preserving bone strength and reducing fracture risk. However, as these results are based on an experimental model, further in vivo studies are needed to confirm their clinical applicability.

Level of evidence

V; Comparative laboratory study.

Le texte complet de cet article est disponible en PDF.

Keywords : Biopsy, Curettage, Pathological fracture, Bone cancer, Femur


Plan


© 2025  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 7

Article 104452- février 2026 Retour au numéro
Article précédent Article précédent
  • Twenty-year infodemiology of bone sarcomas in France (2006–2026): celebrity effect, lexical gap, and limited online impact of awareness campaigns
  • Romain Leonard, Alexandre Rochwerger, Jean-Camille Mattei
| Article suivant Article suivant
  • Assessing tibial slope measurements: A study of methodological consistency and correlation with ACL rupture
  • Luca Tanel, Thais Dutra Vieira, Martin Ecki, Thomas Cucurulo, Jean-Marie Fayard, Bertrand Sonnery-Cottet, Mathieu Thaunat

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.