Diagnostic performance of artificial intelligence for detecting intracranial hemorrhage on brain CT: A Bayesian systematic review and meta-analysis - 11/11/26

Doi : 10.1016/j.neuri.2026.100305 
Tacite Kpanya Mazoba a, ⁎ , Gédéon Mbala Mbuyamba b , Stéphane Yanda Tongo c , Pius Kabututu Zakayi d , Pierre Kafunda Katalay b , Antoine Aundu Molua a
a Department of Radiology and Medical Imaging, Emergency Imaging Unit, Faculty of Medicine, University of Kinshasa, Kinshasa, Congo 
b Department of Mathematics and Computer Science, Optimization and Machine Learning Laboratory (OPTIMALL), Faculty of Science, University of Kinshasa, Kinshasa, Congo 
c Department of Radiology and Medical Imaging, Neuroradiology Unit, Faculty of Medicine, University of Kinshasa, Kinshasa, Congo 
d Department of Basic Sciences, Molecular Biology Unit, Faculty of Medicine, University of Kinshasa, Kinshasa, Congo 

⁎ Corresponding author.

Abstract

Background

Intracranial hemorrhage (ICH) requires rapid and accurate diagnosis. Artificial intelligence (AI) may support ICH detection on brain CT, particularly where radiological expertise is limited.

Objective

To assess the diagnostic performance of AI for ICH detection on brain CT and identify factors associated with performance variability.

Methods

Following PRISMA-DTA recommendations, diagnostic accuracy studies providing sufficient data to construct 2×2 tables were systematically identified. Independent validation cohorts were the primary analytical units, with overlapping datasets excluded from primary pooling (Forty-six studies). Sensitivity and specificity were jointly estimated using a Bayesian bivariate random-effects model. Bayesian subgroup and meta-regression analyses examined validation setting, reference standard, model purpose, and target condition.

Results

The Bayesian bivariate random-effects model yielded a pooled sensitivity of 91.3% (95% CrI, 89.0–93.3%) and specificity of 95.4% (95% CrI, 93.7–96.6%). The positive and negative likelihood ratios were 19.69 (95% CrI, 14.41–26.99) and 0.091 (95% CrI, 0.070–0.116), respectively, with a diagnostic odds ratio of 216.7 (95% CrI, 131.8–354.3). The sensitivity analysis restricted to eight low-risk-of-bias studies yielded sensitivity of 90.3% (95% CrI, 81.2–95.2%) and specificity of 93.4% (95% CrI, 86.7–96.4%). In separate meta-regression models, expert-based reference standards were associated with higher sensitivity (β = 0.713; 95% CrI, 0.173–1.249; posterior probability, 99.5%), and clinical/real-world validation with higher specificity (β = 0.602; 95% CrI, 0.001–1.175; posterior probability, 97.5%).

Conclusion

AI showed high diagnostic accuracy for intracranial hemorrhage detection on brain CT, but low-certainty evidence and heterogeneity limit generalizability. Prospective, external, multicenter validation should assess clinical outcomes and workflow impact, including in resource-limited settings.

Le texte complet de cet article est disponible en PDF.

Keywords : Artificial intelligence, Deep learning, Intracranial hemorrhage, Computed tomography, Diagnostic accuracy, Bayesian meta-analysis, Resource-limited settings


Plan


© 2026  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 6 - N° 4

Article 100305- décembre 2026 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.