S'abonner

Redesigning blood transfusion services: A process excellence tools-driven quality improvement initiative - 18/11/26

Doi : 10.1016/j.tracli.2026.10.008 
Ankita Nigam a, Pandeep Kaur a, ⁎ , Bava U. Davood b, Anuneet Tripathi c, Tarun Dhawan d, Anand Mani Tripathi e
a Department of Immunohematology and Blood Transfusion, National Institute of Medical Sciences and Research, NIMS University, Jaipur, Rajasthan, India 
b Department of Transfusion Medicine and Blood Bank, All India Institute of Medical Sciences, Bibinagar, Hyderabad, Telangana, India 
c Department of General Medicine, National Institute of Medical Sciences and Research, NIMS University, Jaipur, Rajasthan, India 
d Department of Immunohematology and Blood Transfusion, National Institute of Medical Sciences and Research, NIMS University, Jaipur, Rajasthan, India 
e Department of General Medicine, National Institute of Medical Sciences and Research, NIMS University, Jaipur, Rajasthan, India 

⁎ Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 18 November 2026

Highlights

•
Combined Lean Six Sigma, RCA, CAPA and PDCA redesigned blood-centre workflow.
•
Issue/reserve turnaround time fell 59% and donor waiting time fell 44%.
•
Delays across five categories fell by 70 to 99% post-intervention ( P < 0.001).
•
Wastage halved, QC failures resolved, incidents fell from 75 to 29.

Le texte complet de cet article est disponible en PDF.

Abstract

Background and aim

Delays in blood component processing strain transfusion services and may harm patients. This study evaluated the impact of structured process excellence tools on operational efficiency, delay incidence and quality indicators at a tertiary care blood centre.

Materials and methods

Prospective pre–post quality improvement study (July 2024 to December 2025). Consecutive inclusion yielded 1,494 episodes (747 in-hospital blood requests and 747 donor encounters). Phase I established baseline parameters; phase II applied Lean Six Sigma DMAIC, Root Cause Analysis (RCA), Corrective and Preventive Action (CAPA) and the Plan-Do-Check-Act (PDCA) cycle; phase III re-measured identical parameters. Welch's t -test and Chi 2 tests were used; P < 0.05 was considered significant.

Results

Issue/reserve turnaround time decreased from 48.3 ± 20.9 to 19.8 ± 4.5 minutes (−59.0%, P < 0.001). Donor waiting time decreased from 50.6 ± 9.8 to 28.5 ± 2.7 minutes (−43.7%, P < 0.001). Delay incidence decreased across all five categories ( P < 0.001). Wastage rate decreased from 0.83% to 0.34% and component QC failure from 0.92% to 0%. Incidents decreased from 75 to 29 ( P < 0.001). Transfusion-transmitted infection rate was unchanged. The C/T ratio remained below the conventionally used utilisation benchmark of 2.5 in both phases (1.85 before intervention and 1.84 after intervention).

Conclusion

A structured, multi-component quality-improvement programme developed using common process excellence tools was associated with improved operational efficiency, reduced delays, and better selected quality indicators in a tertiary-care blood centre. Controlled and multicentre studies incorporating inventory and blood-group-specific measures are required to evaluate sustainability and wider applicability.

Le texte complet de cet article est disponible en PDF.

Keywords : Blood centre, Lean Six Sigma, Quality improvement, Turnaround time, Plan-Do-Check-Act, Root cause analysis


Plan


© 2026  Société francophone de transfusion sanguine (SFTS). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.