S'abonner

Evaluation of the diagnostic performance of an implant marginal bone loss measurement method based on deep learning - 18/11/26

Doi : 10.1016/j.jormas.2026.103079 
Huaxin Sui a, Hongyu Fu a, Zhihan Zhang b, Jing Liao c, Hu Chen d, e, f, g, ⁎
a Department of Stomatology, Peking University First Hospital, Xicheng District, Beijing 100034, China 
b Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Haidian District, Beijing 100081, China 
c Department of Endodontics, Peking University School and Hospital of Stomatology, Haidian District, Beijing, 100081, China 
d Department of Prosthodontics, Peking University School and Hospital of Stomatology, Haidian District, Beijing, 100081, China 
e Center of Digital Dentistry, Peking University School and Hospital of Stomatology, Haidian District, Beijing, 100081, China 
f National Engineering Laboratory for Digital and Material Technology of Stomatology, Haidian District, Beijing, 100081, China 
g Key Laboratory of Digital Stomatology of Chinese Academy of Medical Sciences and National Health Commission (NHC), Haidian District, Beijing 100081, China 

⁎ Corresponding author at: Department of Prosthodontics, Peking University School and Hospital of Stomatology, No. 22 Zhongguancun South Avenue, Haidian District, Beijing 100081, China. Department of Prosthodontics Peking University School and Hospital of Stomatology No. 22 Zhongguancun South Avenue Haidian District Beijing 100081 China

Abstract

Objectives

To evaluate the diagnostic performance of the YOLOv8-pose model for automated measurement of mesial and distal peri-implant marginal bone loss on periapical radiographs.

Methods

In this retrospective study, 162 images were divided into training (n = 144) and validation (n = 18) sets; 46 images formed an independent test set. Six anatomical key points were annotated and verified as the gold standard. The model was tested at thresholds of bone loss ≥0.5 mm, ≥1.0 mm, and ≥2.0 mm. F1-score was additionally calculated for each threshold.

Results

At the 0.5 mm threshold, the model achieved 95.35% sensitivity, 100% specificity, 100% positive predictive value (PPV), and 90.7% mesial-distal diagnostic consistency. At the 1.0 mm threshold, sensitivity was 91.67%, specificity 82.14%, PPV 73.33%, and consistency 58.14%. At the 2.0 mm threshold, sensitivity dropped to 30.43%, while specificity remained high at 95.97%, with 53.85% PPV and 72.1% consistency. Median key point localization errors ranged from 0.76 mm to 1.05 mm, with no statistically significant difference among groups (P > 0.05).

Conclusions

The YOLOv8-pose model shows excellent diagnostic performance, especially for early mild bone loss. This artificial intelligence tool serves as an auxiliary early-screening tool rather than a comprehensive diagnostic tool covering all severities of bone loss; it can assist clinicians in standardized, efficient, and early screening assessment of peri-implant diseases.

Advances in knowledge

This study validates a keypoint-based deep learning approach for automated and consistent measurement of peri-implant marginal bone loss on periapical radiographs, supporting early objective screening-level assessment of radiographic peri-implant marginal bone-loss changes for clinician reference.

Le texte complet de cet article est disponible en PDF.

Keywords : Dental implants, Marginal bone loss, Deep learning, Periapical radiography, Key point detection


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 127 - N° 6

Article 103079- décembre 2026 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.