Measurement Calibration of Two-Dimensional DSA Images When the Target Deviates from the Isocenter - 23/11/26

Doi : 10.1016/j.neuri.2026.100311 
Kuizhong Wang a, ⁎ , Yuan Dong a, Lubin Yan a, Xiuli Zhao b
a Department of Neurosurgery, Jinan Third People's Hospital (Affiliated Hospital of Jining Medical University), Jinan, China 
b Department of Interventional Radiology, Jinan Third People's Hospital (Affiliated Hospital of Jining Medical University), Jinan, China 

⁎ Corresponding author:Department of Neurosurgery, Jinan Third People's Hospital (Affiliated Hospital of Jining Medical University), No.1 Wangsheren Beijie Rd., Jinan, Shandong Province 250132, China Department of Neurosurgery Jinan Third People's Hospital (Affiliated Hospital of Jining Medical University) No.1 Wangsheren Beijie Rd. Jinan Shandong Province 250132 China

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Manuscrit accepté. Disponible en ligne depuis le Monday 23 November 2026

Abstract

Measurement accuracy in two-dimensional digital subtraction angiography (2D-DSA) images is compromised when the target deviates from the isocenter. This study aimed to derive simplified calibration equations for non-isocentric scenarios and to validate their accuracy.

Using two Siemens single-plane DSA systems (Artis Pheno and Artis Zee), a 10-mm steel sphere was measured at non-isocentric positions across multiple C-arm angulations and table movements. Sphere diameter was measured on the DSA workstation, and errors were compared before and after calibration. Using the Artis Zee, seven steel spheres were arranged in a plane parallel to the detector and offset from the isocenter. Images were acquired in frontal and lateral projections at different table positions and magnification fields of view (FOVs). Measured diameters were compared across positions and FOVs.

For the single sphere imaged at multiple angulations and table movements, pre-calibration maximum errors were 22.05% and 24.70% for the two systems; after calibration, maximum errors were reduced to 3.18% and 2.15%, respectively. The standard deviations of the paired measured and calibrated values differed significantly for both systems (both P < 0.001). For the seven-sphere array imaged in frontal and lateral projections, no statistically significant difference in measured diameter was observed across different positions ( χ 2 = 0.88, P = 0.990 ) or across different magnification FOVs ( χ 2 = 2.32, P = 0.803 ).

The proposed non-isocentric calibration method significantly improves measurement accuracy in 2D-DSA imaging, with important implications for neurointerventional procedures requiring precise vessel measurements.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

•
Non-isocentric targets without calibration cause errors in 2D-DSA measurements.
•
The calibration equations were derived using DICOM parameters.
•
Maximum error decreased from >24% to <3.2% after calibration.
•
The method is valid for various C-arm angulations and table positions.
•
It improves the reliability of vessel sizing in neurointerventional procedures.

Le texte complet de cet article est disponible en PDF.

Keywords : Digital subtraction angiography, Two-dimensional image, Isocenter, Non-isocentric, Calibration, Accurate measurement


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.