S'abonner

Pragmatic application of ultrasound in the follow-up of intraductal papillary mucinous neoplasm. Should we overcome MRI-only surveillance? - 26/11/26

Doi : 10.1016/j.clinre.2026.102974 
Marco Ferronato 1, ⁎ , Valentina Cipriano 1, Elena Bartoli 1, Chiara Quarneti 1, Andrea Neri 1, Daniele Carrello 1, Laura Capitanio 1, Elena Mazzotta 1, Carlo Ingaldi 2, Andrea Palloni 3, Mariacristina Di Marco 3, Claudio Ricci 2, Riccardo Casadei 2, Marina Migliori 1
1 IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy, Internal Medicine Unit 
2 IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy, Pancreas and endocrine surgery Unit 
3 IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy, Oncology Unit 

⁎ Correspondance author. Dott. Marco Ferronato, via Albertoni 15, Bologna, Italy. Tel +39 051-2142292, Fax +39 051-2142290 via Albertoni 15 Bologna Italy
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Thursday 26 November 2026

Highlights

•
Abdominal ultrasound reliably visualizes IPMNs and some worrisome features.
•
No safety differences detected between US-based and MRI-based surveillance, though events were few.
•
US-based surveillance reduced loss to follow-up rate after multivariable adjustment.
•
Among BD-IPMN <20 mm US-based surveillance independently reduced costs by 67%.
•
Exploratory data: 40% of low-risk BD-IPMN developed worrisome features beyond 5 years.
•
US may reduce surveillance burden; prospective confirmation of long-term safety is needed.

Le texte complet de cet article est disponible en PDF.

ABSTRACT

Background and aims

Guidelines recommend MRI-based surveillance for BD-IPMNs, imposing a burden on healthcare systems. Abdominal ultrasound (US) reliably visualizes IPMNs and some worrisome features (WF). We aimed to evaluate the safety and potential benefits of integrating US into surveillance protocols.

Methods

Retrospective study of 644 patients with BD-IPMN, stratified by surveillance strategy: US-assisted (≥2 US during follow-up) versus standard surveillance, and MRI-limited (MRI only for significant changes on US) versus MRI-prevalent surveillance.

Results

Both US-assisted and MRI-limited strategies showed no significant differences in clinical outcomes with reference groups (mortality, unresectable cancer, appropriate surgery; all p>0.09), lower loss-to-follow-up (12.0% vs 32.9%, p<0.01; 13.2% vs 28.4%, p<0.01), higher guideline adherence (80.3% vs 68.1%, p<0.01; 79.5% vs 70.8%, p=0.03), and lower costs (€478.3 vs €780.9; €272.7 vs €857.4, p<0.01). Multivariable logistic regression confirmed lower loss-to-follow-up after adjustment for confounders (adjusted OR 0.28 and 0.34, both p<0.01), while adjusted adherence remained significantly higher for US-assisted surveillance (OR 0.42, p<0.01). In a generalized linear model including IPMN <20 mm, MRI-limited surveillance independently reduced costs by 67% (adjusted cost ratio 0.33, 95% CI 0.26-0.42, p<0.01) regardless of baseline WF and cyst modification. In an exploratory analysis, even for cysts <20 mm with no baseline WF, risk of developing a new WF persisted beyond the 5-year threshold (conditional probability of 40% between years 5 and 10).

Conclusions

US-based surveillance was associated with improved compliance, guideline adherence and cost-effectiveness, without detectable safety signals. An MRI-limited approach in well-visualized BD-IPMN <20 mm appears promising for long term surveillance.

Le texte complet de cet article est disponible en PDF.

Keywords : abdominal ultrasound, cost-effectiveness, guidelines, adherence, IPMN


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.