Comparative Diagnostic Performance and Safety of 19-Gauge EUS-Guided, 22-Gauge EUS-Guided, and Percutaneous Liver Biopsy: A Systematic Review and Network Meta-analysis - 26/11/26
, Rongxing Zhou 1, ⁎, ⁎ 
Highlights |
• | First network meta-analysis comparing 19-G EUS-LB, 22-G EUS-LB, and PC-LB. |
• | Diagnostic adequacy was comparable across the three biopsy strategies. |
• | 19-G EUS-LB showed the most favorable overall tissue-yield ranking. |
• | 22-G EUS-LB was associated with a shorter longest sample length. |
• | Safety outcomes were comparable among all three biopsy strategies. |
Abstract |
Background |
Endoscopic ultrasound-guided liver biopsy (EUS-LB) has emerged as an alternative to percutaneous liver biopsy (PC-LB), but the relative performance of 19-gauge and 22-gauge EUS-LB remains uncertain. We compared the diagnostic performance, tissue yield, and safety of these three strategies.
Methods |
PubMed, the Cochrane Library, and Google Scholar were searched from inception to December 20, 2025. Eligible adult studies comparing 19-gauge EUS-LB, 22-gauge EUS-LB, or PC-LB were included. The primary outcome was diagnostic adequacy; secondary outcomes were total sample length (TSL), longest sample length (LSL), complete portal tract (CPT) yield, and adverse events (AEs). Pairwise and Bayesian network meta-analyses were performed.
Results |
Seventeen studies involving 1,767 patients were included. Network estimates showed no statistically significant differences in diagnostic adequacy among the three strategies. Nineteen-gauge EUS-LB had the highest ranking probabilities for diagnostic adequacy (SUCRA, 0.89), TSL (0.96), and CPT yield (0.91). Twenty-two-gauge EUS-LB produced a significantly shorter LSL than 19-gauge EUS-LB (mean difference, −5.95 mm; 95% CI, −11.34 to −0.68) and PC-LB. No statistically significant differences in AEs were identified among the strategies.
Conclusions |
Nineteen-gauge EUS-LB showed the most favorable ranking profile for diagnostic adequacy and tissue yield, although most comparative estimates were not statistically significant. Twenty-two-gauge EUS-LB was associated with a shorter LSL, while no clear safety differences were detected. These rankings do not establish superiority, and the absence of statistically significant differences in AEs does not establish equivalent safety. Biopsy selection should be individualized according to tissue requirements, procedural context, local expertise, and patient characteristics.
Le texte complet de cet article est disponible en PDF.Keywords : liver biopsy, percutaneous liver biopsy, endoscopic ultrasound-guided liver biopsy, Network Meta-Analysis
Plan
| Present address: No. 37 Guoxue Alley, Wuhou District, Chengdu, Sichuan Province, 610041, P.R. China |
Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?
