S'abonner

Why the proximal interphalangeal joint stiffens: A morphological synthesis of osseous geometry, collateral ligament mechanics and the volar plate - 27/11/26

Doi : 10.1016/j.morpho.2026.101245 
Dinara Irismetova a, Mansur Tolibov b, ⁎ , Sardorjon Saloydinov c, Utkirjon Madatov d, Iroda Nurmatova b
a Khoja Akhmet Yassawi International Kazakh-Turkish University, Turkistan 161200, Kazakhstan 
b Samarkand State Medical University, Samarkand 140100, Uzbekistan 
c Tashkent State Technical University Named After Islam Karimov, Tashkent 100095, Uzbekistan 
d Samarkand State University named after Sharof Rashidov, Samarkand 140104, Uzbekistan 

⁎ Corresponding author.

Highlights

•
Near-axial collateral origins limit overall ligament excursion at the PIP joint.
•
PIP stability depends on position-specific tension sharing among stabilisers.
•
Volar plate–check-rein structures become relatively slack during flexion.
•
Flexed immobilisation may promote adaptive shortening and flexion contracture.
•
PIP and MCP joints stiffen differently because their ligament geometry differs.

Le texte complet de cet article est disponible en PDF.

Summary

The proximal interphalangeal (PIP) joint is essential to hand function and susceptible to post-traumatic stiffness. Its stabilisers require an integrated anatomical and biomechanical interpretation. This narrative review qualitatively synthesised human cadaveric, morphometric, biomechanical and imaging studies identified through the reported PubMed, Scopus and Web of Science search to January 2026 and reference-list checking. Targeted supplementary literature checks during revision addressed volar plate dynamics, retinacular ligaments and distal interphalangeal (DIP) mechanics. Twenty-one primary studies are tabulated; no meta-analysis was performed. Original screening counts are unavailable, and the selection diagram describes the narrative workflow. The evidence supports position-dependent behaviour of individual collateral-ligament portions and dynamic reconfiguration of the volar plate. Near-axial collateral origins help explain limited attachment-distance change in a simplified hinge model, but do not establish that head width is less important. PIP flexion contracture plausibly involves shortening and adhesions of volar periarticular tissues together with changes in the extensor and retinacular apparatus. Differences from the metacarpophalangeal joint involve joint type, articular geometry and soft-tissue organisation. DIP findings show partial mechanical similarities but do not establish an identical contracture pathway. PIP stiffness is best interpreted as a multifactorial, position-dependent process. This synthesis supports preserving tissue excursion when injury stability permits, while prospective evidence is needed to establish causal mechanisms and optimal immobilisation strategies.

Le texte complet de cet article est disponible en PDF.

Keywords : Proximal interphalangeal joint, Collateral ligament, Volar plate, Biomechanics, Joint stiffness, Hand therapy


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 371

Article 101245- mars 2026 Retour au numéro
Article précédent Article précédent
  • Exploring the morphology and clinical relevance of accessory canals: A scoping review of classification, variations, and endodontic implications
  • Mohmed Isaqali Karobari, Abdul Habeeb Adil, Niher Tabassum Snigdha
| Article suivant Article suivant
  • Morphological analysis of the hippocampus in rats exposed to Zika virus on embryonic day 9: Evidence of male vulnerability
  • G.d.B. de Aguiar, M. Gomes da Costa, E. de Souza Hoeper, A.P. Martini, C.A. Netto, P.M. Roehe, T.F. Teixeira, A.P. Muterle Varela, L. Orlandi Pereira

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.