Highlights

•
The great saphenous vein (GSV) being a longest vein in the human body holds significant clinical importance in vascular surgeries.
•
Precise spatial relationships of GSV-SN are critical to minimize iatrogenic nerve injury during invasive procedures.
•
Despite the established clinical relevance, thorough ultrasonographic data on the distance of these structures remain sparse.
•
This study provides anatomical and ultrasonographic data that may inform procedural planning, while their impact on procedural safety or complication rates remain to be established prospectively.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

The great saphenous vein (GSV) runs in close proximity to the saphenous nerve (SN) at medial malleolus (MM). Precise spatial relationship of GSV-SN at MM are critical to minimize iatrogenic injuries during invasive procedures. Despite the established clinical relevance, thorough ultrasonographic (USG) data on the distance of these structures remain sparse. This study aimed to determine USG anatomy of GSV-SN at MM, GSV diameter, its subcutaneous depth, distances of GSV-SN; GSV-MM and correlate these with anthropometric variables such as age, height, weight and body mass index (BMI).

Methods

Sixty healthy adult volunteers (120 limbs) aged 20–70 years were involved in this study. USG parameters recorded bilaterally were: GSV diameter, its subcutaneous depth, and distances of GSV-SN; GSV-MM at the ankle.

Results

Mean GSV diameter at MM was 8.90 ± 0.76 mm, with statistically significant right-left differences ( P = 0.013). Mean subcutaneous depth of GSV was 15.30 ± 2.23 mm with no statistically significant right-left differences ( P = 0.584). Mean GSV-SN distance was 3.91 ± 0.92 mm across all limbs with no statistically significant right-left asymmetry ( P = 0.737). Mean GSV-MM distance was 15.38 ± 3.36 mm with an excellent bilateral symmetry (right: 15.36 ± 3.15 mm – left: 15.40 ± 3.58 mm; P = 0.949). GSV diameter and its subcutaneous depth showed a strong positive correlation with BMI.

Conclusion

This study provides anatomical and ultrasonographic data that may inform procedural planning, while their impact on procedural safety or complication rates remain to be established prospectively.

Le texte complet de cet article est disponible en PDF.

Keywords : Great saphenous vein, Saphenous nerve, Medial malleolus, Ultrasonography, Spatial relationships, Indian population, Correlates


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 371

Article 101244- mars 2026 Retour au numéro
Article précédent Article précédent
  • Clinical utility of prenatal exome sequencing after normal chromosomal microarray in fetuses with structural anomalies
  • M. Perriere, W. Darwiche, K. Messaoudi, M. Gallet, B. Bonte, S. Delmas Lanta, B. Demeer, F. Jobic, G. Morin, V. Magry, G. Jedraszak
| Article suivant Article suivant
  • Coronary arteries, myocardial bridges, and coronary dominance: A cadaveric study
  • J.C. Cavalcante, W.G. Lira-Bandeira, M.B. Montello, A.K.R. Rebouças, Q.O. Chaves, I.C Medeiros Júnior, R.R.M. de Lima, F.V.L. Ladd, B.J. Abreu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.