S'abonner

Detection of the presence of second mesiobuccal canal in the maxillary first molar with bitewing radiography using MediXpar - 27/11/26

Doi : 10.1016/j.morpho.2026.101146 
S. Celik Ozsoy a, E. Tavmasat Mercantas a, b, E.C. Kaya a, S. Satir a, ⁎ , U.O. Osmanoglu c, T. Felek d
a Oral and Maxillofacial Radiology Department, Faculty of Dentistry, Karamanoğlu Mehmetbey University, 70200 Karaman, Turkey 
b Oral and Maxillofacial Radiology Department, Faculty of Dentistry, Ankara Yıldırım Beyazıt University, Ankara, Turkey 
c Faculty of Medicine, Karamanoğlu Mehmetbey University, Biostatistics, Turkey 
d Institute of Applied Science, Akdeniz University, Turkey 

* Corresponding author.

Highlights

•
The presence of MB2, due to bucco-lingual morphological changes in the pulp cavity of maxillary molars, can be partially demonstrated by the MediXpar depth analysis.
•
It appears that depth analysis performed on retrospective bitewing radiographs using the MediXpar can provide a preliminary estimate of the presence of MB2 in maxillary molars and can be used as a guide for indicating CBCT imaging.

Le texte complet de cet article est disponible en PDF.

Summary

Background

The second mesiobuccal canal (MB2) variation, which is frequently found especially in maxillary first molars, is a significant cause of complications. The aim of this study was to perform pulp depth analysis of maxillary first molars using bitewing radiographs and to evaluate the role of the MediXpar in the diagnosis of MB2.

Methods

Retrospectively 64 cases (46 patients) in which bitewing radiographs and CBCT were included in the study. CBCT were used as the gold standard for MB2 detection. The MediXpar was used for pulp depth analysis from bitewing radiographs. Four different ROIs created by manual segmentation were determined for pulp depth analysis and pixel count, DATS, PowerDATS and edge density data were recorded for each.

Results

No significant difference was detected between molars with MB2 ( n = 32) and without MB2 ( n = 32), according to the pixel count, DATS and edge density data obtained from four different ROIs. Significant difference was detected in the PowerDATS results for each ROI, and without MB2 was significantly higher. In the presence of MB2, the ratio of samples with PowerDATS results below 90 was 84%, 78%, 68% and 75% for ROI1, ROI2, ROI3 and ROI4, respectively. In the absence of MB2, the ratio of samples with PowerDATS results above 90 was 59%, 75%, 75% and 75%, respectively.

Conclusions

Bitewing radiographs analysed with the MediXpar can help predict the presence of an MB2 canal. Teeth with an MB2 had notably lower PowerDATS values than those without, indicating this noninvasive analysis may guide the need for confirmatory CBCT.

Le texte complet de cet article est disponible en PDF.

Keywords : Bitewing radiography, Dental anatomy, Maxillary molars, Mesiobuccal root, Root canal


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 371

Article 101146- mars 2026 Retour au numéro
Article précédent Article précédent
  • Human fleshy muscle–bone attachments are histologically distinct from classical entheses: A comparative exploratory study
  • Hesham N. Mustafa
| Article suivant Article suivant
  • Clinical utility of prenatal exome sequencing after normal chromosomal microarray in fetuses with structural anomalies
  • M. Perriere, W. Darwiche, K. Messaoudi, M. Gallet, B. Bonte, S. Delmas Lanta, B. Demeer, F. Jobic, G. Morin, V. Magry, G. Jedraszak

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.