Exploratory LSTM analysis of frontotemporal fNIRS signals for differentiating schizophrenia from bipolar disorder in a depressive episode - 27/11/26

Doi : 10.1016/j.neuri.2026.100313 
Yi-Hua Huang 1, 2, Bo-Han Chou 3, Chang-Yi Lee 4, Sanford P.C. Hsu 2, 5, 6, Chun-Yi Zac Lo 1, Yi-Min Wang 4, Chia-Wei Sun 4, 7, 8, ⁎
1 Institute of Intelligent Bioelectrical Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan 
2 Department of Rehabilitation and Technical Aid Center, Taipei Veterans General Hospital, Taipei, Taiwan 
3 Brain Mental Health Clinic, Hsinchu, Taiwan 
4 Biomedical Optical Intelligent Lab, Department of Photonics, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan 
5 Division of General Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan 
6 School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan 
7 Medical Device Innovation and Translation Center, National Yang Ming Chiao Tung University, Hsinchu, Taiwan 
8 Center for Healthy Longevity and Aging Sciences, National Yang Ming Chiao Tung University, Hsinchu, Taiwan 

⁎ Corresponding author:

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Manuscrit accepté. Disponible en ligne depuis le Friday 27 November 2026

Abstract

Schizophrenia (SZ) and bipolar disorder (BD) can present overlapping symptoms, motivating research on objective adjuncts to clinical assessment. We examined two region-of-interest oxygenated-hemoglobin (HbO 2 ) time series acquired with functional near-infrared spectroscopy (fNIRS) during a verbal fluency task using long short-term memory (LSTM) models. Archived five-fold tables reported mean accuracies of 0.873 for healthy controls (HC) versus SZ, 0.862 for HC versus BD, and 0.865 for SZ versus BD. The displayed mean for HC versus the combined patient group was not treated as a primary result because one fold value (0.958) has an unverifiable denominator. The same cross-validation procedure informed both model selection and performance estimation, so the internal estimates are likely optimistically biased and should not be interpreted as performance in new participants. An archived direct three-class test matrix from a single 80/20 split contained 18 observations (6 per class) and yielded accuracy 0.722, balanced accuracy 0.722, and macro-F1 0.664; five of six SZ observations were classified as BD. Without short-separation correction, the discriminative signals cannot be attributed confidently to cortical activity. Given the single-centre cohort, non-nested internal evaluation, and incomplete analysis records, these findings document an archival proof-of-concept and do not establish unbiased generalization, diagnostic accuracy, or clinical utility.

Le texte complet de cet article est disponible en PDF.

Keywords : functional near-infrared spectroscopy, schizophrenia, bipolar depression, deep learning, LSTM, internal evaluation


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.