Does pyrocarbon interposition shoulder arthroplasty (PISA) really prevent bone erosion in the shoulder? A minimum 10 years follow up - 28/11/26
, Jean David Werthel b, Thibault Druel a, e, Stefan Bauer c, Gilles Walch d, Philippe Collotte dAbstract |
Background |
Pyrocarbon (PyC) interposition shoulder arthroplasty (PISA) was developed to treat glenohumeral osteoarthritis (GHOA) while preserving bone stock and limiting glenoid wear. Long-term data on bone erosion and implant survival remain limited. This study reports the minimum 10-year clinical and radiographic outcomes of PISA in relatively young patients.
Methods |
We retrospectively reviewed all consecutive PISA procedures performed by a single surgeon between 2009 and 2013 for GHOA (8 primary GHOA, 8 post instability arthropathy, 5 post traumatic osteoarthritis, 2 avascular necrosis, and 2 post arthroscopic procedures) with an intact rotator cuff on preoperative CT. Twenty-five patients (median age, 52 years; interquartile range (IQR), 45–57 years) were evaluated at a median follow-up of 12 years (IQR, 12–13 years). Clinical assessment included range of motion, Constant score (CS), Subjective Shoulder Value (SSV), and satisfaction. Standardized radiographs obtained postoperatively, at 2 years, and at final follow-up (>10 years) were analyzed for humeral and glenoid wear, and implant subsidence. Failure was defined as implant removal.
Results |
Four patients were reoperated (16%), including three (12%) who were revised (2 to reverse total shoulder arthroplasty and 1 to metal hemiarthroplasty). Kaplan–Meier implant survival was 88% (95% CI, 67–96%) at 10 years. In retained implants, anterior elevation, external and internal rotation, and CS improved significantly (all p < .001); the median SSV was 80% (IQR, 70%–90%), 19 of 22 patients were satisfied or very satisfied, and 20 resumed their previous activities. Radiographically, humeral densification and peri-implant radiolucency were observed in 23/24 (96%) shoulders at the 1-year follow-up. At final follow-up, humeral wear was graded as none-to-mild in 13 shoulders, moderate in 3, and severe in 6, with significant implant subsidence over time (p = .002). Glenoid erosion was none-to-mild in 5 shoulders, moderate in 14, and severe in 3.
Conclusions |
PyC interposition shoulder arthroplasty did not prevent progressive bone erosion, and the degree of proximal humeral wear in some patients is concerning for potential future revision, particularly in young individuals. However, long-term functional outcomes and satisfaction were good overall when the patients retained the PISA. These findings temper the initial rationale supporting pyrocarbon interposition to prevent bone erosion.
Level of evidence |
IV.
Le texte complet de cet article est disponible en PDF.Keywords : Pyrocarbon, Bone erosion, Shoulder osteoarthritis, Arthroplasty