S'abonner

Comparison of a Reduced Radiation Fluoroscopy Protocol to Conventional Fluoroscopy During Uncomplicated Ureteroscopy - 06/08/11

Doi : 10.1016/j.urology.2010.11.020 
Daniel J. Greene, Christopher F. Tenggadjaja, Ryan J. Bowman, Gautum Agarwal, Kamyar Y. Ebrahimi, D. Duane Baldwin
Department of Urology, Loma Linda University Medical Center, Loma Linda, California 

Reprint requests: D. Duane Baldwin, Department of Urology, Loma Linda University School of Medicine, 11234 Anderson Street, Room A560, Loma Linda, CA, 92354

Résumé

Objectives

Although the long-term effects of radiation exposure are not completely predictable, the principle of keeping radiation exposure “as low as reasonably achievable” should be used. The purpose of this study was to compare fluoroscopy times before and after the implementation of a protocol designed to reduce fluoroscopy usage during ureteroscopy.

Methods

A retrospective review was conducted of 300 consecutive ureteroscopy patients at a single institution. Patients undergoing simple ureteroscopy without ancillary procedures or balloon dilation were further evaluated to determine the effect of a reduced fluoroscopy protocol. The protocol included several measures, including use of a laser-guided C-arm, use of a designated fluoroscopy technician and substitution of visual for fluoroscopic cues during ureteroscopy. Fluoroscopy times were compared between groups using a paired t test with P < .05 considered significant.

Results

Ureteroscopy cases before protocol implementation (n = 30) were compared with procedures after implementation (n = 30). Stone size and location were similar between groups. Protocol implementation significantly reduced the mean fluoroscopy exposure from 86.1 seconds (range 30-300) to 15.5 seconds (range 0-54; P < .001). There was no difference in mean operative time (74.2 vs 65.1 minutes; P = .14), or complications (2 patients vs 2 patients; P = 1) between groups. No complication in either group could be ascribed to the fluoroscopic technique.

Conclusions

The reduced fluoroscopy protocol resulted in an 82% reduction in fluoroscopy time without altering patient outcomes. These simple radiation-reducing techniques add no technical difficulty and improve safety for the patient, surgeon, and operating room staff by lowering radiation exposure.

Le texte complet de cet article est disponible en PDF.

Plan


© 2011  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 78 - N° 2

P. 286-290 - août 2011 Retour au numéro
Article précédent Article précédent
  • Quantification of Preoperative Stone Burden for Ureteroscopy and Shock Wave Lithotripsy: Current State and Future Recommendations
  • Sutchin R. Patel, Stephen Y. Nakada
| Article suivant Article suivant
  • Multicenter Analysis of Postoperative CT Findings After Percutaneous Nephrolithotomy: Defining Complication Rates
  • Michelle Jo Semins, Leonid Bartik, Ben H. Chew, Elias S. Hyams, Mitchell Humphreys, Nicole L. Miller, Ojas Shah, Ryan F. Paterson, Brian R. Matlaga

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.