S'abonner

Rapid determination of anti-heparin/platelet factor 4 antibody titers in the diagnosis of heparin-induced thrombocytopenia - 28/08/11

Doi : 10.1016/S0002-9343(03)00080-9 
Lorenzo Alberio, MD a, ⁎ , Sabine Kimmerle a, Annalies Baumann, Behrouz Mansouri Taleghani, MD a, Franziska Demarmels Biasiutti, MD a, Bernhard Lämmle, MD a
a Central Hematology Laboratory, University Hospital, Inselspital, Bern, Switzerland 

*Requests for reprints should be addressed to Lorenzo Alberio, MD, Central Hematology Laboratory, University Hospital, Inselspital, CH-3010 Bern, Switzerland

Abstract

Purpose

Heparin-induced thrombocytopenia is mediated by antibodies directed against the heparin–platelet factor 4 (heparin/PF4) complex. Our aim was to investigate whether rapid measurement of anti-heparin/PF4 antibodies could improve the diagnostic workup of patients with suspected heparin-induced thrombocytopenia.

Methods

We examined 148 consecutive patients in our laboratory between January 1995 and June 2001 for suspected heparin-induced thrombocytopenia. Clinical data allowed retrospective assessment of the likelihood of heparin-induced thrombocytopenia. Antibodies against the heparin/PF4 complex were detected by a rapid particle gel immunoassay.

Results

Anti-heparin/PF4 antibodies were detected in 69 (47%) of the 148 patients, at dilution titers from 1 to 256. Clinically “likely” or “very likely” heparin-induced thrombocytopenia was significantly more common in patients with titers ≥4 (95% [39/41]) than in those with undetectable antibodies (13% [9/70]; P <0.0001), a titer of 1 (18% [4/22]; P <0.0001), or a titer of 2 (33% [2/6]; P = 0.001). All 19 samples with a positive platelet aggregation test had anti-heparin/PF4 antibody titers of at least 4, including 15 samples with titers ≥32. Thromboembolic complications in heparin-treated patients were significantly more prevalent in patients with titers ≥4 (63% [26/41]) than in those with undetectable antibodies (8% [6/79]; P <0.0001) or a titer of 1 (9% [2/22]; P <0.0001). Of the 11 patients with a titer of 1 who were maintained on heparin, none developed worse thrombocytopenia or thromboembolic complications.

Conclusion

Anti-heparin/PF4 antibody titers, which can be measured rapidly and reproducibly using a particle gel immunoassay, can be used as a confirmatory test to complement a clinical likelihood score among patients with suspected heparin-induced thrombocytopenia.

Le texte complet de cet article est disponible en PDF.

Keywords : Thrombocytopenia, Heparin, Platelet factor 4(PF4), Antibody titer, Diagnosis


Plan


 Dr. Alberio is supported by a grant from the Swiss National Science Foundation (grant 3200-065337.01).


© 2003  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 114 - N° 7

P. 528-536 - mai 2003 Retour au numéro
Article précédent Article précédent
  • Association between complex coronary artery stenosis and unstable angina and the extent of plaque inflammation
  • Martijn Meuwissen, Allard C van der Wal, Karel T Koch, Chris M van der Loos, Steven A.J Chamuleau, Peter Teeling, Robbert J de Winter, Jan G.P Tijssen, Anton E Becker, Jan J Piek
| Article suivant Article suivant
  • Tramadol and acetaminophen combination tablets in the treatment of fibromyalgia pain: a double-blind, randomized, placebo-controlled study
  • Robert M Bennett, Marc Kamin, Rezaul Karim, Norman Rosenthal

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.