Abstract

Study objective: St-segment elevation is used to make early decisions about using thrombolytic therapy in patients with suspected myocardial infarction. This study was performed to assess interobserver and intraobserver variation in subjects' measurements of ST-segment elevation in isolated ECG complexes.

Methods: We performed a masked, paired-sample experiment. Emergency physicians, emergency medicine residents, and senior medical students were asked to measure ST-segment elevations in a packet of 40 isolated single ECG complexes from patients with proven myocardial infarction. Each packet consisted of 20 pairs of randomly ordered ECG complexes. Subjects were masked to the duplicate nature of the pairs of complexes. Estimates of each ST-segment measurement pair were subtracted; summary statistics were calculated for these differences. Agreement between first and second ST-segment estimates was analyzed by using weighted κ values. Tests for differences in the paired ST-segment estimations among groups were carried out with 1-factor analysis of variance.

Results: Fifty-two subjects completed the study and measured a total of 2,070 ST segments (1,035 pairs). The mean difference in segment height among all groups was 0.28 mm (95% confidence interval [Cl], 0.27 to 0.30). The median was 0.2 mm, the 80th percentile was 0.5 mm, and the 95th percentile was 0.9 mm. Statistical agreement between paired ST-segment measurements was very good (κ=0.85; 95% Cl, 0.83 to 0.87). However, by using a threshold of at least 2.0 mm for ST-segment elevation, 143 (14%) of 1,035 paired estimations (95% Cl, 12% to 16%) produced inconsistent classifications. Physicians, residents, and students had similar median differences (P=.77). Some subjects exhibited more intraobserver variation than did others, and some complexes were associated with greater intraobserver variation than others (P<.001).

Conclusion: One fifth of the time, intraobserver measurements of paired ST-segment elevations differed by more than half a millimeter. Independent interpretations of the same ST segment by the same reader as greater than or equal to 2.0 mm or not were different 14% of the time. This could result in misclassification of candidates for thrombolytic therapy.

Le texte complet de cet article est disponible en PDF.

* Presented at the Society of Academic Emergency Medicine annual meeting, Chicago, IL, May 1998, and at the Faculty of Accident and Emergency Medicine/Society of Academic Emergency Medicine combined meeting, Oxford, UK, September 1998.


© 1999  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 34 - N° 4P1

P. 448-452 - octobre 1999 Retour au numéro
Article précédent Article précédent
  • An economic analysis of the ottawa knee rule
  • Graham Nichol, Ian G Stiel, George A Wells, Lars S Juergensen, Andreas Laupacis
| Article suivant Article suivant
  • Emergency medical service agency definitions of response intervals
  • Harvey W Meislin, Jennifer B Conn, Carol Conroy, Mark Tibbitts

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.