S'abonner

Assessment of central and peripheral fusion and near and distance stereoacuity in intermittent exotropic patients before and after strabismus surgery - 08/09/11

Doi : 10.1016/S0002-9394(99)00079-3 
Cem Yildirim, MD a, , Fatih Mehmet Mutlu, MD b, Yin Chen, MPH c, Halil Ibrahim Altinsoy, MD b
a University of Pamukkale, Denizli, Turkey (Dr Yildirim) 
b Gulhane Military Medical Academy, Ankara, Turkey (Drs Mutlu and Altinsoy) 
c Washington University School of Medicine, St Louis, Missouri, USA (Mr Chen) 

*Reprint requests to Cem Yildirim, MD, 17, Sokak 48-6, Bahcelievler, 06490, Ankara, Turkey; fax: +90-258-242-1134

Abstract

PURPOSE: To determine whether central fusion and distance stereoacuity are useful as objective measures in assessing the need for and success of surgery for intermittent exotropia (X[T]).

METHODS: A prospective, institutional, clinical trial was conducted of 26 consecutive patients with X(T) who were undergoing strabismus surgery in whom fusion (central and peripheral) and stereoacuity (at near and distance) were assessed preoperatively and postoperatively, as well as in 112 normal subjects. To obtain accurate measurements with sensory tests, the lower age was limited to 5 years for inclusion. A successful surgical alignment was defined as an exotropia of 10 prism diopters or less at 6 m. Sensory and motor outcome measures were determined 1 year after surgery.

RESULTS: The successful surgical alignment rate was 69%. All patients with X(T) demonstrated peripheral fusion, whereas 35% demonstrated central suppression preoperatively and postoperatively. Central fusion was not predictive of surgical outcome (P = .078); however, there was a trend toward less surgical success in patients with central suppression. Patients with X(T) exhibited good near stereoacuity before and after surgery. Distance stereoacuity in patients with X(T) preoperatively was significantly diminished compared with normal subjects (P < .001) and was improved in 58% postoperatively. Patients who achieved successful surgical alignment had a greater likelihood of demonstrating distance stereoacuity improvement postoperatively than patients who failed to achieve successful surgical alignment (P = .003). Patients with central suppression were unlikely to improve their distance stereoacuity postoperatively (P = .014).

CONCLUSIONS: Successful surgery may improve distance stereoacuity. Better distance stereoacuity and central fusion are frequently associated with better surgical success in X(T).

Le texte complet de cet article est disponible en PDF.

Plan


© 1999  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 128 - N° 2

P. 222-230 - août 1999 Retour au numéro
Article précédent Article précédent
  • Third cranial nerve palsy in children
  • Linda A Schumacher-Feero, K.W Yoo, Fernando Mendiola Solari, Albert W Biglan
| Article suivant Article suivant
  • Editorial

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.