S'abonner

Nitrate-enhanced thallium 201 single-photon emission computed tomography imaging in hibernating myocardium - 08/09/11

Doi : 10.1016/S0002-8703(99)70127-4 
Ronald J. Oudiz, MD, David E. Smith, MD, Arnold J. Pollak, MD, Ismael Mena, MD, Shelley M. Shapiro, MD, PhD, Leonard E. Ginzton, MD, Kenneth A. Narahara, MD

Abstract

Objectives This study tested the usefulness of nitrate-enhanced thallium 201 imaging for detecting myocardial viability. Background Previous work suggests that nitrates enhance the ability of 201Tl imaging to detect viable myocardium. Methods Eighteen patients with coronary artery disease underwent 201Tl imaging at rest, after 4 hours of redistribution, and during intravenous nitroglycerine infusion (mean dose = 5.96 ± 5.37 μg/kg/min). Twelve patients had their echocardiograms repeated after revascularization. Perfusion and wall motion were scored from 0 to 2 (absent to normal). Results All the regions identified as viable by the rest/redistribution pair of scans were identified as viable by the rest/nitroglycerine pair of scans. Ninety-one percent of these regions were identified as viable by the single nitroglycerine scan alone. In patients who underwent revascularization, the total 201Tl perfusion score improved from 193 to 214 after revascularization (P = .009). Wall motion score improved from 151 to 168 after revascularization (P = .09). Both the rest/nitroglycerine and rest/redistribution studies correctly predicted 14 (88%) of 16 regions that improved after revascularization. Most importantly, the rest/nitroglycerine and rest/redistribution studies were able to predict postrevascularization myocardial viability (absence of akinesis or dyskinesis after revascularization), with a sensitivity of 95% and 92%, respectively, and a predictive accuracy of 84.4%. Conclusions Nitroglycerine infusion during 201Tl imaging is a useful technique for detecting underperfused, viable myocardium, requires less time to perform than rest/redistribution imaging, and may allow detection of viable myocardium with a single 201Tl single-photon emission computed tomographic study. (Am Heart J 1999;138:369-75.)

Le texte complet de cet article est disponible en PDF.

Plan


 From Saint John’s Cardiovascular Research Center, Harbor-UCLA Research and Education Institute, and the Department of Medicine, Division of Cardiology Harbor-UCLA Medical Center.
 Reprint requests: Ronald J. Oudiz, MD, Division of Cardiology, Box 405, Harbor-UCLA Medical Center, 1000 W Carson St, Torrance, CA 90509.E-mail: [email protected]
 0002-8703/99/$8.00 + 0   4/1/96662


© 1999  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 138 - N° 2

P. 369-375 - août 1999 Retour au numéro
Article précédent Article précédent
  • Preserved diagnostic utility of dobutamine stress echocardiography in pacemaker-dependent patients with absolute chronotropic incompetence
  • Hakan Oral, William F. Armstrong, David S. Bach
| Article suivant Article suivant
  • Clinical correlates of the initial and long-term cost of coronary bypass surgery and coronary angioplasty
  • Mark A. Hlatky, Derek B. Boothroyd, Maria Mori Brooks, Carla Winston, Allan Rosen, William J. Rogers, Guy S. Reeder, Hugh C. Smith, Thomas J. Ryan, Bertram Pitt, Patrick L. Whitlow, Robert D. Wiens, Daniel B. Mark

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.