Coronary artery morphologic features after coronary rotational atherectomy: Insights into mechanisms of lumen enlargement and embolization - 12/09/11
Abstract |
The coronary arteries and myocardium from two patients who died after coronary rotational atherectomy were analyzed to gain insights into the mechanisms of lumen enlargement and to document embolization of calcified plaque. Rotational atherectomy resulted in sharp cuts in plaque, producing a relatively smooth luminal surface. When extensive nodular calcific atherosclerosis was present, the luminal surface was focally uneven with exposure of jagged calcified plaque to blood flow. Deep plaque fissures and medial dissections were also seen. These fissures may have been created by the rotoblator or by adjunctive balloon angioplasty. Multiple calcific atheroemboli were present after rotoblator use in plaques containing extensive nodular calcification; in moderately calcified plaque only one small atheroembolus was found. Thus embolization of calcified plaque can occur after rotational atherectomy and may correlate with the severity of plaque calcification. Rotational atherectomy produces a focally smooth, sharp-edged, luminal surface, a lumen enlargement mechanism different from balloon angioplasty.