Screening and Characterization of Staphylococcus aureus from Ophthalmology Clinic Surfaces: A Proposed Surveillance Tool - 13/03/14

Doi : 10.1016/j.ajo.2014.01.008 
Rachel E. Reem a, Joany Van Balen b, Armando E. Hoet b, c, Colleen M. Cebulla a,
a Department of Ophthalmology, Havener Eye Institute, The Ohio State University Wexner Medical Center, Columbus, Ohio 
b Department of Veterinary Preventive Medicine, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio 
c Division of Epidemiology, College of Public Health, The Ohio State University, Columbus, Ohio 

Inquiries to Colleen M. Cebulla, 915 Olentangy River Road, Suite 5000, Columbus, OH 43212

Abstract

Purpose

To screen environmental surfaces of an outpatient ophthalmic clinic for methicillin-susceptible and methicillin-resistant Staphylococcus aureus (MSSA and MRSA); to identify the most commonly contaminated surfaces and to phenotype and genotype all collected isolates.

Design

A single institution, 1-year prospective environmental study.

Methods

Commonly touched surfaces in examination rooms and common areas were targeted and sampled on a quarterly basis for 1 year. Samples were collected using electrostatic cloths and swabs. S. aureus was isolated using nonselective and selective media. Morphologic characteristics and standard biologic testing were used to confirm staphylococcal species. S. aureus isolates were phenotypically (Kirby-Bauer method) and genotypically characterized (mecA confirmation, SCCmec typing and pulsed-field gel electrophoresis). Dendrogram analysis was used to establish genetic relatedness between the isolates.

Results

Of 112 total samples, 27 (24%) and 5 (4%) were MSSA- and MRSA-positive, respectively. Both community-associated (SCCmec IV, USA300) and hospital-associated (SCCmec II, USA100) MRSA isolates were found. No single surface remained consistently positive with the same isolate over time, and molecular analysis demonstrated high levels of diversity among isolates. Doorknobs, slit-lamp headrests and chinrests, and computer keyboards were commonly found to be contaminated.

Conclusions

The proposed surveillance protocol successfully allowed the detection of both MSSA and MRSA contaminating important high-touch surfaces in a representative ophthalmology clinic. Frequently contaminated surfaces must be targeted for routine cleaning and disinfection because there is a constant introduction of clones over time. Hence, other clinics may consider implementing and adapting surveillance tools, like the one described here, to help them control these important nosocomial pathogens.

Le texte complet de cet article est disponible en PDF.

Plan


 Dr Reem's current affiliation is the Department of Ophthalmology, Nationwide Children's Hospital, Columbus, Ohio.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 157 - N° 4

P. 781 - avril 2014 Retour au numéro
Article précédent Article précédent
  • Endophthalmitis Caused by Streptococcal Species: Clinical Settings, Microbiology, Management, and Outcomes
  • Ajay E. Kuriyan, Kathleen D. Weiss, Harry W. Flynn, William E. Smiddy, Audina M. Berrocal, Thomas A. Albini, Darlene Miller
| Article suivant Article suivant
  • Dry Eye Exacerbation in Patients Exposed to Desiccating Stress under Controlled Environmental Conditions
  • Alberto López-Miguel, Marisa Tesón, Vicente Martín-Montañez, Amalia Enríquez-de-Salamanca, Michael E. Stern, Margarita Calonge, María J. González-García

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.