Choroidal Analysis in Healthy Eyes Using Swept-Source Optical Coherence Tomography Compared to Spectral Domain Optical Coherence Tomography - 30/05/14

Doi : 10.1016/j.ajo.2014.02.034 
Mehreen Adhi a, Jonathan J. Liu b, Ahmed H. Qavi a, Ireneusz Grulkowski b, Chen D. Lu b, Kathrin J. Mohler b, Daniela Ferrara a, Martin F. Kraus b, c, Caroline R. Baumal a, Andre J. Witkin a, Nadia K. Waheed a, Joachim Hornegger c, James G. Fujimoto b, Jay S. Duker a,
a New England Eye Center, Tufts Medical Center, Boston, Massachusetts 
b Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 
c Pattern Recognition Lab and School of Advanced Optical Technologies (SAOT), University Erlangen-Nuremberg, Erlangen, Germany 

Inquiries to Jay S. Duker, New England Eye Center, 800 Washington Street, Boston, MA 02111

Abstract

Purpose

To compare analyses of choroidal thickness and volume in healthy eyes measured concurrently with prototype long-wavelength swept-source optical coherence tomography (OCT) and commercially available spectral-domain optical coherence tomography (OCT) with and without enhanced depth imaging (EDI).

Design

Prospective cross sectional study.

Methods

The study included 19 healthy subjects (19 eyes), who were prospectively recruited to undergo 2 consecutive imaging sessions on the same randomly selected eye using spectral domain OCT and a prototype long-wavelength swept-source OCT. On spectral domain OCT, 2 line scans, 1 with and 1 without EDI, and 1 volumetric scan were obtained. On swept-source OCT, 1 line scan and 1 volumetric scan were obtained. Scan patterns on swept-source OCT were created to simulate those available on Cirrus HD-OCT to keep the time of image acquisition constant. Swept-source OCT volumetric scans were motion corrected using a novel registration algorithm. Choroidal thickness and volume were analyzed.

Results

The choroidoscleral interface was clearly visualized in 19/19 (100%) of eyes imaged by swept-source OCT, compared to 14/19 (73.6%) and 13/19 (68.4%) eyes imaged by spectral domain OCT, with and without EDI, respectively. There was no significant difference in choroidal thickness measurements on the line scans obtained on either system (P = 0.10). Choroidal volume could not be assessed on volumetric scans from spectral domain OCT. Mean choroidal volume from swept-source OCT volumetric scans was 11.77 ± 3.13 mm3 (6.43 mm3-17.15 mm3).

Conclusion

This is the first study that compares simultaneously a prototype long-wavelength swept-source OCT to a commercially available spectral domain OCT for a detailed analysis of choroid in healthy eyes. Swept-source OCT shows potential for better choroidal analysis. Studies using swept-source OCT in diseased eyes will further define this new technology's utility in chorioretinal diseases.

Le texte complet de cet article est disponible en PDF.

Plan


 Dr Grulkowski was visiting from the Institute of Physics, Nicolaus Copernicus University, Torun, Poland. K. Mohler was visiting from the Ludwig Maximilian University of Munich, Munich, Germany.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 157 - N° 6

P. 1272 - juin 2014 Retour au numéro
Article précédent Article précédent
  • Long-Term Effects of Multiple Intravitreal Antivascular Endothelial Growth Factor Injections on Intraocular Pressure
  • Yoon Jeon Kim, Kyung Rim Sung, Kyoung Sub Lee, Soo Geun Joe, Joo Yong Lee, June-Gone Kim, Young Hee Yoon
| Article suivant Article suivant
  • The Argus II Retinal Prosthesis: 12-Month Outcomes from a Single-Study Center
  • Stanislao Rizzo, Claudia Belting, Laura Cinelli, Luca Allegrini, Federica Genovesi-Ebert, Francesco Barca, Emanuele di Bartolo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.