S'abonner

Timing of retinal redetachment after removal of intraocular silicone oil tamponade - 08/09/11

Doi : 10.1016/S0002-9394(99)00201-9 
Jost B Jonas, MD a, , Wido M Budde, MD a, Harald L.J Knorr, MD a
a Department of Ophthalmology and Eye Hospital, University Erlangen-Nürnberg, Erlangen, Germany 

*Reprint requests to Jost B. Jonas, MD, Universitäts-Augenklinik, Schwabachanlage 6, 91054 Erlangen, Germany; fax: 49-9131-8534436

Abstract

PURPOSE:

To evaluate the interval between removal of intraocular silicone oil tamponade and retinal redetachment after pars plana vitrectomy, and to investigate factors influencing the length of the interval.

PATIENTS AND METHODS:

The retrospective study included 42 eyes of 42 consecutive patients who experienced a retinal redetachment after silicone oil had been removed 8.0 ± 6.2 months after an initial pars plana vitrectomy including intraocular silicone oil (5,000 centistokes) tamponade. Pars plana vitrectomy had been performed for proliferative vitreoretinopathy caused by complicated rhegmatogenous retinal detachment.

RESULTS:

The retina redetached 2 days to 5.5 months after silicone oil removal (mean ± SD, 1.3 ± 1.4 months; median, 18 days). Thirteen (30%) of all 42 redetachments occurred in the first 9 days, 21 (50%) of all 42 retinal redetachments occurred in the first 18 days, and 32 (75%) of all 42 retinal redetachments occurred in the first 50 days. The interval between silicone oil removal and retinal redetachment was statistically (by analysis of variance) independent of the method of silicone removal (transpupillary drainage vs via pars plana sclerotomies), refractive error of the eye (P = .62), time between initial pars plana vitrectomy and silicone oil removal (P = .99), visual acuity before silicone oil removal (P = .26), type of anesthesia (P = .69), gender (P = .80), and age (P = .48) of the patients.

CONCLUSION:

The risk of retinal redetachment decreases steeply with increasing time after silicone oil removal. Three to 5 months after oil removal, retinal redetachment becomes unlikely. The time of retinal redetachment is statistically independent of the method of silicone oil removal, refractive error, time between the preceding pars plana vitrectomy and silicone oil removal, visual acuity before silicone oil removal, type of anesthesia, and gender and age of the patents. These data may be important for scheduling reexaminations and for counseling patients in their planned activities after removal of intraocular silicone oil tamponade.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was supported by Deutsche Forschungsgemeinschaft, Bonn, Germany (SFB 539).


© 1999  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 128 - N° 5

P. 628-631 - novembre 1999 Retour au numéro
Article précédent Article précédent
  • Optical coherence tomography of successfully repaired idiopathic macular holes
  • Masahito Imai, Hiroyuki Iijima, Teruhiko Gotoh, Shigeo Tsukahara
| Article suivant Article suivant
  • Editorial

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.