Abstract

Background

Mechanically aligned (MA) total knee arthroplasty (TKA) is affected by disappointing functional outcomes in spite of the recent improvements in surgical precision and implant designs. This might suggest the existence of intrinsic technical limitations. Our study aims to compare the prosthetic and native trochlear articular surfaces and to estimate the extent of collateral ligament imbalance, which is technically uncorrectable by collateral ligament release when TKA implants are mechanically aligned.

Study hypothesis

Conventional MA technique generates a high rate of prosthetic overstuffing of the distal groove, distal lateral trochlear facet and distal lateral femoral condyle (Hypothesis 1), and technically uncorrectable collateral ligament imbalance (hypothesis 2)? Disregarding the distal femoral joint line obliquity (DFJLO) when performing femoral cuts explains distal lateral femoral prosthetic stuffing and uncorrectable imbalance (hypothesis 3)?

Methods

Twenty patients underwent a conventional MA TKA. Pre-operative MRI-based 3D knee models were generated and MA TKA was simulated. Native and prosthetic trochlear articular surfaces were compared using in-house analysis software. Following the automatic determination by the planning software of the size of the extension and flexion gaps, an algorithm was applied to balance the gaps and the frequency and amplitude of technically uncorrectable knee imbalance were estimated.

Results

The conventional MA technique generates a significant slight distal lateral femoral prosthetic overstuffing (mean 0.6mm, 0.8mm, 1.25mm for the most distal lateral facet point, groove, and at the most distal point of lateral femoral condyle, respectively) and a high rate of type 1 and 2 uncorrectable knee imbalance (30% and 40%, respectively). The incidence of distal lateral prosthetic overstuffing (trochlea and condyle) and uncorrectable knee imbalance were strongly to very strongly correlated with the DFJLO (r=0.53 to 0.89).

Conclusion

Conventional MA technique for TKA generates frequent lateral distal femoral prosthetic overstuffing and technically uncorrectable knee imbalance secondary to disregarding the DFJLO when adjusting the femoral component frontal and axial rotations, respectively.

Level of evidence

level 4.

El texto completo de este artículo está disponible en PDF.

Keywords : Total knee replacement, Mechanical alignment, Imbalance, Laxity, Trochlea facet, Retinacula ligament, Stuffing


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 7

P. 1057-1067 - novembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Alignment options for total knee arthroplasty: A systematic review
  • C. Rivière, F. Iranpour, E. Auvinet, S. Howell, P.-A. Vendittoli, J. Cobb, S. Parratte
| Artículo siguiente Artículo siguiente
  • The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis
  • C. Rivière, F. Iranpour, S. Harris, E. Auvinet, A. Aframian, P. Chabrand, J. Cobb

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.