The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis - 07/11/17

Doi : 10.1016/j.otsr.2017.06.016 
C. Rivière a, , F. Iranpour a, S. Harris a, E. Auvinet a, A. Aframian a, P. Chabrand b, J. Cobb a
a Department of joint replacement, the MSK Lab, Charing Cross Campus, Laboratory Block, Fulham Palace Rd, W6 8RP London, UK 
b Institut des sciences du mouvement, université Aix-Marseille, 171, avenue de Luminy, 13009 Marseille, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Kinematic alignment (KA) technique is an alternative technique for positioning a TKA, which aims a patient-specific implant positioning in order to reproduce the pre-arthritic knee anatomy. Because reliability in implant positioning is of interest to obtain reproducible good functional results, our study tests the hypothesis that the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically aligned femoral component are similar.

Methods

Preoperative knee magnetic resonance imaging (MRI) and postoperative knee computed tomography (CT) of 13 patients implanted with a KA Persona® TKA (Zimmer, Warsaw, USA) using manual instrumentation (kinematically-aligned TKA procedure pack®, Zimmer Biomet, Warsaw, USA) were segmented to create 3D femoral models. The kinematic alignment position of the femoral component was planned on the 3D model created from the preoperative MRI. Differences in the positions of the planned and surgically implanted kinematically-aligned femoral component were determined with in-house analysis software.

Results

The average differences between the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically-aligned femoral component were inferior to 1mm and no statistically significant. In terms of variability, 62% (8/13) of performed implants matched all four positions within 1.5mm, and the maximum difference was 3mm.

Conclusion

In this small series, intraoperative kinematic positioning of the femoral component with the specific manual instrumentation closely matched the planned position, which suggests that this technique reliably aligned the flexion-extension axis of the femoral component to the cylindrical axis.

Level of evidence

Level 3.

El texto completo de este artículo está disponible en PDF.

Keywords : Total Knee Arthroplasty, Kinematic alignment, Reproducibility, Positioning, Reliability, Cylindrical axis


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 7

P. 1069-1073 - novembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Mechanical alignment technique for TKA: Are there intrinsic technical limitations?
  • C. Rivière, F. Iranpour, E. Auvinet, A. Aframian, K. Asare, S. Harris, J. Cobb, S. Parratte
| Artículo siguiente Artículo siguiente
  • Does curettage–cement packing for treating giant cell tumors at the knee lead to osteoarthritis?
  • A. Caubère, S. Harrosch, M. Fioravanti, G. Curvale, A. Rochwerger, J.-C. Mattei

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.