Suscribirse

Measurement variability of liver metastases from neuroendocrine tumors on different magnetic resonance imaging sequences - 28/02/18

Doi : 10.1016/j.diii.2017.12.009 
T. Lestra a, , L. Kanagaratnam b, S. Mulé a, A. Janvier a, H. Brixi c, G. Cadiot c, A. Dohan d, C. Hoeffel a, e
a Department of radiology, Reims university hospital, 51092 Reims, France 
b Department of research and innovation, Reims university hospital, 51100 Reims, France 
c Department of gasto-enterology, Reims university hospital, 51100 Reims, France 
d Department of radiology A, Hopital Cochin, and University Paris 5-Descartes, 75014 Paris, France 
e Reims university hospital, CRESTIC, Champagne-Ardenne university, 51867 Reims, France 

Corresponding author. Department of radiology, CHU de Reims, hôpital Maison-Blanche, 45, rue Cognacq-Jay, 51092 Reims cedex, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To assess dimension measurement variability of liver metastases from neuroendocrine tumors (LMNET) on different magnetic resonance imaging (MRI) sequences.

Material and methods

In this institutional review board-approved retrospective study from January 2011 to December 2012, all liver MRI examinations performed at our department in patients with at least one measurable LMNET according to response evaluation criteria in solid tumors (RECIST1.1) were included. Up to two lesions were selected on T2-weighted MR images. Three reviewers independently measured long axes of 135 hepatic metastases in 30 patients (16 men, 14 women, mean age 61±11.4 (SD) years; range 28–78 years), during two separate reading sessions, on T2-weighted, diffusion-weighted MRI (DWI) (b; 50, 400, 800 s/mm2) and arterial, portal and late phases after intravenous administration of a gadolinium chelate. Intraclass-correlation coefficients and Bland–Altman plots were used to assess intra-and interobserver variability.

Results

Intra- and interobserver agreements ranged between 0.87–0.98, and 0.88–0.97, respectively. Intersequence agreements ranged between 0.92 [95%CI: 0.82–0.98] and 0.98 [95%CI: 0.93–0.99]. 95% limits of agreement for measurements were −10.2%,+8.9% for DWI (b=50s/mm2) versus −21.9%,+24.2% and −15.8,+17.2% for arterial and portal phases, respectively.

Conclusion

An increase<9% in measurement and a decrease of −10% on DWI should not be considered as true changes, with 95% confidence, versus 24% and −22% on arterial and 17%, −16% on portal phases, respectively. DWI might thus be the most reliable MR sequence for monitoring size variations of LMNETs.

El texto completo de este artículo está disponible en PDF.

Keywords : Liver metastasis, Neuroendocrine tumors (NET), Magnetic resonance imaging (MRI), Response evaluation criteria in solid tumors (RECIST), Interobserver variability


Esquema


© 2017  Editions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 2

P. 73-81 - février 2018 Regresar al número
Artículo precedente Artículo precedente
  • Correlation of quantitative MR imaging findings with symptoms in patients with incidentally detected inflammatory sinonasal disease
  • O. Kilickesmez, O. Onerci Celebi, M. Yalcinkaya, A.R. Gokduman, Y. Karagoz, O. Yigit
| Artículo siguiente Artículo siguiente
  • Volumetric measurement of hepatic tumors: Accuracy of manual contouring using CT with volumetric pathology as the reference method
  • L.F. Pupulim, M. Ronot, V. Paradis, S. Chemouny, V. Vilgrain

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.