Suscribirse

Thoughts on a new surgical assistance method for implanting the glenoid component during total shoulder arthroplasty. Part 1: Statistical modeling of the native premorbid glenoid - 31/03/19

Doi : 10.1016/j.otsr.2018.10.024 
Julien Berhouet b, c, , Luc Favard a, c, David Boas b, Théo Voisin b, Mohamed Slimane b
a Service d’orthopédie traumatologie, faculté de médecine de Tours, université François Rabelais de Tours, CHRU Trousseau, 1C, avenue de la République, 37170 Chambray-les-Tours, France 
b Équipe reconnaissance de forme et analyse de l’image, université François Rabelais de Tours, école d’ingénieurs polytechnique universitaire de Tours, laboratoire d’informatique EA6300, 64, avenue Portalis, 37200 Tours, France 
c Western France Orthopedics Society (SOO)/HUGORTHO, 18, rue de Bellinière, 49800 Trélazé, France 

Corresponding author. Service d’orthopédie traumatologie, faculté de médecine de Tours, université François Rabelais de Tours, CHRU Trousseau, 1C, avenue de la République, 37170 Chambray-les-Tours, France.France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The aim of this study was to identify points on the scapula that can be used to predict the anatomy of the native premorbid glenoid.

Material and methods

Forty-three normal scapulas reconstructed in 3D and positioned in a common coordinate system were used. Twenty points distributed over the blade of the scapula (portion considered normal and used as a reference) and the glenoid (portion considered pathological and needing to be reconstructed) were captured manually. Thirteen distances (X) between two points not on the glenoid and 31 distances (Y) between two points of which at least one was on the glenoid were then calculated automatically. A multiple linear regression model was applied to calculate the Y distances from the X distances. The best four equations were retained based on their coefficient of determination (R2) to explain a point on the glenoid being reconstructed (p<0.05). In the first scenario, the glenoid was modeled assuming it was completely destroyed. In the second scenario, only the inferior portion of the glenoid was worn.

Results

For a completely destroyed glenoid, the mean error for a chosen distance for a given point on the glenoid was 2.4 mm (4.e-3mm; 12.5mm). For a partially damaged glenoid, the mean error was 1.7mm (4.e-3mm; 6.5mm) for the same distance evaluated for a given point on the glenoid.

Discussion/Conclusion

The proposed statistical model was used to predict the premorbid anatomy of the glenoid with an acceptable level of accuracy. A surgeon could use this information during the preoperative planning stage and during the actual surgery by using a new surgical assistance method.

El texto completo de este artículo está disponible en PDF.

Keywords : Premorbid glenoid, Multiple linear regression, Statistical prediction, Surgical assistance, Shoulder arthroplasty


Esquema


 Article issued from the Orthopaedics and Traumatology Society of Western France (SOO) – 2017 Tours meeting.


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 2

P. 203-209 - avril 2019 Regresar al número
Artículo precedente Artículo precedente
  • Is CT indispensable in shoulder arthroplasty in 2019?
  • Pierre-Henri Flurin, François Sirveaux
| Artículo siguiente Artículo siguiente
  • Views on a new surgical assistance method for implanting the glenoid component during total shoulder arthroplasty. Part 2: From three-dimensional reconstruction to augmented reality: Feasibility study
  • Julien Berhouet, Mohamed Slimane, Maxime Facomprez, Min Jiang, Luc Favard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.