Suscribirse

Views on a new surgical assistance method for implanting the glenoid component during total shoulder arthroplasty. Part 2: From three-dimensional reconstruction to augmented reality: Feasibility study - 31/03/19

Doi : 10.1016/j.otsr.2018.08.021 
Julien Berhouet a, b, c, , Mohamed Slimane b, Maxime Facomprez b, Min Jiang b, Luc Favard a, c
a Service d’orthopédie traumatologie 1C, faculté de médecine de Tours, université François-Rabelais de Tours, CHRU Trousseau, avenue de la République, 37170 Chambray-lès-Tours, France 
b Équipe reconnaissance de forme et analyse de l’image, laboratoire d’informatique fondamentale et appliquée de Tours EA6300, école d’ingénieurs polytechnique universitaire de Tours, université François-Rabelais de Tours, 64, avenue Portalis, 37200 Tours, France 
c Société d’orthopédie de L’Ouest (SOO)/HUGORTHO, 18, rue de Bellinière, Trélazé, France 

Corresponding author. Service d’orthopédie traumatologie 1C, université François-Rabelais de Tours, CHRU Trousseau, avenue de la République, 37170 Chambray-lès-Tours, France.Service d’orthopédie traumatologie 1C, université François-Rabelais de Tours, CHRU Trousseauavenue de la RépubliqueChambray-lès-Tours37170France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The main goal of this study was to propose a new method of surgical assistance for the implantation of a total shoulder prosthesis, with the use of augmented reality (AR). The advantage of this approach is that it supplements information, on the one hand pre-existing or disappeared due to a pathological process, such as the premorbid glenoid, and on the other hand already existing but not accessible to the surgeon during the procedure, such as the so-called “hidden” face of the scapula.

Material and methods

Several information preparation steps were needed. The first consisted in the three-dimensional (3D) rendering of the pathological glenoid, from a point cloud corresponding to the premorbid glenoid based on previously developed regression equations. A library of “healthy” generic glenoids was then created by hierarchical bottom-up analysis. From this database, a so-called adequate normal generic glenoid was fused and matched to the pathological glenoid reconstructed using a morphing technique. An experimental AR application was constructed. Smart glasses were used to display the prepared 3D information.

Results

A pathological 3D glenoid was reconstructed and used for the AR application. A complete display of the scene, reconstructed glenoid and full scapula was obtained. However, an offset from reality was observed. The main limitations were technical, related to the connected tool itself and the operating software.

Discussion/Conclusion

This was a feasibility study of the different steps required to apply AR, from information preparation to its visualization. A new parameter crossing experiment is needed to optimize each step of this process.

Level of evidence

IV, Basic science study.

El texto completo de este artículo está disponible en PDF.

Keywords : Augmented reality, Three-dimensional reconstruction, Premorbid glenoid, Shoulder prosthesis


Esquema


 Article issued from the SOO (the Orthopedics and Traumatology Society of Western France), Works of the Congress of Tours (2017).


© 2018  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 2

P. 211-218 - avril 2019 Regresar al número
Artículo precedente Artículo precedente
  • Thoughts on a new surgical assistance method for implanting the glenoid component during total shoulder arthroplasty. Part 1: Statistical modeling of the native premorbid glenoid
  • Julien Berhouet, Luc Favard, David Boas, Théo Voisin, Mohamed Slimane
| Artículo siguiente Artículo siguiente
  • Cement augmentation of glenoid baseplate screws does not improve primary stability in reversed shoulder arthroplasty: A cadaveric study
  • Benjamin Bockmann, Martin Bäumlein, Rainer Koch, Jens Figiel, Philipp Lechler, René Aigner, Christopher Bliemel, Ludwig Oberkircher, Steffen Ruchholtz, Michael Frink

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.