Suscribirse

Temporal evaluation of the microwave ablation zone and comparison of CT and gross sizes during the first month post-ablation in swine lung - 26/04/19

Doi : 10.1016/j.diii.2018.10.008 
H. Kodama a, E. Ueshima a, K. Howk b, S.W. Lee b, J.P. Erinjeri a, c, S.B. Solomon a, c, G. Srimathveeravalli a,
a Department of Radiology, Interventional Radiology Service, Memorial Sloan-Kettering Cancer Center, 1275 York avenue, 10065 New York, USA 
b Medtronic Inc, Massachusetts, USA 
c Department of Radiology, Weill Cornell Medical College, New York, USA 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The purpose of this study was to investigate the development and evolution of the microwave ablation (MWA) lesion in the normal lung by using a swine model at various time points and to compare post-procedural computed tomography (CT) and gross pathologic findings during the first month post-ablation.

Materials and methods

Twenty-seven percutaneous MWA procedures were performed on swine lungs at 100W for either 2min (low dose, 18 ablations) or 10min (high dose, 9 ablations). Animals were sacrificed at either 2 days (n=5) or 28 days (n=5) after ablation. All animals underwent CT imaging immediate post-treatment and prior to sacrifice, with additional imaging at 7 and 14 days for the 28-day cohort. After euthanasia, lungs and trachea were removed en bloc and underwent gross pathology analysis.

Results

In both dose treatment groups, CT measurements of the ablation zone were maximum at Day 7 (low dose: 7.50±3.08 cm3; high dose: 24.87±11.34 cm3) and significantly larger compared to the immediate post-ablation measurements (low dose: 2.54±1.81 cm3; P=0.00011; high dose: 9.14±3.42 cm3; P=0.00374). No significant differences in dimensions were observed between CT and gross pathologic images for both high and low dose ablations in both cohorts.

Conclusion

The treatment zone following MWA in the lung can vary in the sub-acute setting, achieving largest size at 7 days post-treatment. Furthermore, measurements from CT closely matched with gross pathologic ablation size.

El texto completo de este artículo está disponible en PDF.

Keywords : Ablation zone, Computed tomography (CT), Lung, Preclinical study, Microwave ablation (MWA)


Esquema


© 2018  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 5

P. 279-285 - mai 2019 Regresar al número
Artículo precedente Artículo precedente
  • Influence of iterative reconstruction and dose levels on metallic artifact reduction: A phantom study within four CT systems
  • J. Greffier, A. Larbi, J. Frandon, P.A. Daviau, J.P. Beregi, F. Pereira
| Artículo siguiente Artículo siguiente
  • Cumulative radiation dose after lung transplantation in patients with cystic fibrosis
  • I. Fitton, M.-P. Revel, P.-R. Burgel, A. Hernigou, V. Boussaud, R. Guillemain, F. Le Pimpec-Barthes, S. Bennani, G. Freche, G. Frija, G. Chassagnon

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.