Suscribirse

Can atrioventricular node ablation be safely performed in patients with permanent His bundle pacing? Data from a French multicentric registry - 09/01/21

Doi : 10.1016/j.acvdsp.2020.10.193 
C. Chaumont 1, , N. Auquier 2, A. Milhem 3, A. Savoure 1, A. Mirolo 1, B. Godin 1, G. Viart 1, A. Al Arnaout 3, E. Popescu 2, H. Eltchaninoff 1, F. Anselme 1
1 Department of Cardiology, Rouen University Hospital, Rouen 
2 Department of Cardiology, Groupe hospitalier du Havre, Le Havre 
3 Department of Cardiology, La Rochelle Hospital, La Rochelle, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Resumen

Introduction

Ventricular rate control is essential in the management of atrial fibrillation. Atrioventricular node ablation (AVNA) and ventricular pacing can be an effective option when pharmacological rate control is insufficient. However, right ventricular pacing induces ventricular desynchronisation in patients with normal QRS and increases the risk of heart failure on long-term. His bundle pacing (HBP) is a physiological alternative. There is still very limited data about the feasibility of AVNA after HBP.

Purpose

To evaluate feasibility and safety of HBP followed by AVNA in patients with non-controlled atrial arrhythmia.

Methods

We included all patients who underwent AVNA for non-controlled atrial arrhythmia after HBP implantation in 3 hospitals. No back-up ventricular lead was implanted. AVNA procedures were performed with 8 mm-tip ablation catheters.

Results

AVNA after HBP lead implantation was performed in 50 patients. AVNA was successful in 36 of 50 patients (72%). Modulation of the AV node conduction was obtained in 8 patients (16%). The mean procedure duration was 44±25min, and mean fluoroscopy duration was 5.9±7.7min. A mean number of 6.6±9.0 RF applications (315±450 s) were delivered to obtain complete/incomplete AV block. Acute HB capture (HBC) threshold increase>1V occurred in 9 patients (18%) with return to baseline value at day 1 in 6. There was no lead dislodgment. Mean HBC threshold after AVNA was 1.25±0.78V@0.5ms. AV node re-conduction was observed in 6 patients (16.7%). No ventricular lead revision was required during the follow-up period. The baseline native QRS duration was 102±21ms and the paced QRS duration was 107±18ms (Fig. 1).

Conclusion

AVNA combined with HBP for non-controlled atrial arrhythmia is feasible and does not compromise HBC but seems technically difficult with significant AV nodal re-conduction rate. The presence of a back-up ventricular lead could have changed our results and would require further evaluation.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2020  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 13 - N° 1

P. 85 - janvier 2021 Regresar al número
Artículo precedente Artículo precedente
  • Cardiac resynchronisation therapy in patients with cardiac amyloidosis: A multicentre retrospective study
  • K. Fischer, N. Lellouche, T. Damy, R. Martins, N. Clementy, A. Bisson, F. Lesaffre, M. Espinosa, R. Garcia, B. Degand, G. Serzian, J. Guichard, G. Laurent, C. Guenancia
| Artículo siguiente Artículo siguiente
  • What can we learn from hyper-responders to cardiac resynchronisation therapy (CRT)? Characteristics and predictors of super response to CRT. An Algerian single centre experience
  • R. Benkouar, M.S. Ait Messaoudene, Y. Aoudia, A. Boudrifa, K. Bouasria, Y. Tir, O. Kassoul, H. Elnajer, L. Ouabdeslem, N. Ali Tatar, M.T. Chentir, Y. Bouhouita

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.