S'abonner

Referral Patterns for Primary Prophylaxis Implantable Cardioverter Defibrillator Therapy for an Urban US Population - 27/09/15

Doi : 10.1016/j.amjcard.2015.07.031 
Eric D. Manheimer, MD , Christian Gonzalez, MD, Jordan Turk, MD, Andrew K. Krumerman, MD, Soo G. Kim, MD, Jay N. Gross, MD, Eugen C. Palma, MD, Michael J. Grushko, MD, John D. Fisher, MD, Kevin J. Ferrick, MD
 Arrhythmia Service, Department of Cardiology, Albert Einstein College of Medicine-Montefiore Medical Center, Bronx, New York 

Corresponding author: Tel: (718) 702-4028; fax: (917) 512-6692.

Abstract

Implantable cardioverter defibrillators (ICDs) have been demonstrated to improve survival for both primary and secondary prevention of sudden cardiac arrest. However, studies suggest that ICD therapy is underused in appropriate candidates. Sex and racial disparities in ICD use have been suggested. We sought to characterize the referral patterns of high-risk patients for the primary prophylaxis of sudden cardiac arrest at a tertiary academic medical center serving a diverse population in an urban US setting. Electronic hospital databases were retrospective reviewed for patients meeting criteria for prophylactic ICD implantation. We evaluated the association of gender, age, race, and primary language with the referral and subsequent implantation of an ICD. We identified 1,055 patients satisfying prophylactic ICD criteria: 600 men, mean age 62.6 years, 27.6% black, 19.3% white, 23.3% Hispanic, and 49.8% primary language of English. Of the 673 patients (63.7%) referred for ICD evaluation, 345 underwent implantation, 125 declined, and 203 had significant co-morbidities that precluded implantation. Gender, race, and primary language were not associated with referral for ICD or with decision to proceed with implantation. Patients of increased age were less likely to be referred for ICD and were more likely to refuse implantation. ICD therapy was not considered in 146 patients eligible for prophylactic implantation. In conclusion, referral rates for ICD consideration were higher at our institution than in previous reports. Nonetheless, 14% of appropriate patients were not considered. This argues for the importance of increased education for patients and referring physicians.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 1212 for disclosure information.


© 2015  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 116 - N° 8

P. 1210-1212 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Comparison of Characteristics and Outcomes of Dabigatran Versus Warfarin in Hypertensive Patients With Atrial Fibrillation (from the RE-LY Trial)
  • Rangadham Nagarakanti, Lars Wallentin, Herbert Noack, Martina Brueckmann, Paul Reilly, Andreas Clemens, Stuart J. Connolly, Salim Yusuf, Michael D. Ezekowitz
| Article suivant Article suivant
  • Effect of Falls on Frequency of Atrial Fibrillation and Mortality Risk (from the REasons for Geographic And Racial Differences in Stroke Study)
  • Wesley T. O'Neal, Waqas T. Qureshi, Suzanne E. Judd, C. Barrett Bowling, Virginia J. Howard, George Howard, Elsayed Z. Soliman

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.