Longitudinal Strain by Automated Function Imaging Detects Single-Vessel Coronary Artery Disease in Patients Undergoing Dipyridamole Stress Echocardiography - 01/10/15

Doi : 10.1016/j.echo.2015.06.001 
Maurizio Cusmà-Piccione, MD, PhD a, Concetta Zito, MD, PhD a, Lilia Oreto, MD a, Myriam D’Angelo, MD a, Sonia Tripepi, MD a, Gianluca Di Bella, MD a, Maria Chiara Todaro, MD a, Giuseppe Oreto, MD a, Bijoy K. Khandheria, MD b, , Scipione Carerj, MD a
a Clinical and Experimental Department of Medicine and Pharmacology, University of Messina, Messina, Italy 
b Aurora Cardiovascular Services, Aurora Sinai/Aurora St Luke’s Medical Centers, University of Wisconsin School of Medicine and Public Health, Milwaukee, Wisconsin 

Reprint requests: Bijoy K. Khandheria, MD, Aurora Cardiovascular Services, 2801 W Kinnickinnic River Parkway, #840, Milwaukee, WI 53215.

Abstract

Background

The aim of this study was to investigate the incremental value of global longitudinal strain (GLS) by automated function imaging in respect to wall motion (WM) for the detection of coronary artery disease (CAD) during dipyridamole stress echocardiography.

Methods

Fifty-two patients (mean age, 65.3 ± 8.7 years; 22 men) underwent dipyridamole stress echocardiography followed by coronary angiography within 1 week. Diagnostic accuracy for the identification of single-vessel CAD was evaluated for WM and GLS. The study population was divided into two groups according to coronary angiographic findings: those with CAD (n = 38; mean age, 67.2 ± 5.9 years; 19 men) and those without CAD (n = 14; mean age, 63.3 ± 6.4 years; three men).

Results

A trend toward lower resting GLS values was found in patients with CAD than in those without (−18.7 ± 2.2% vs −20 ± 2.8%, P = .061). In patients without CAD, GLS progressively increased up to peak dose (from −20 ± 2.8% at rest to −20.7 ± 1.9% at low dose, P = .045; from −20.7 ± 1.9% at low dose to −21.5 ± 3.1% at peak dose, P = .032), whereas in patients with CAD, an increase of GLS from rest to low dose (from −18.7 ± 2.2% to −19.2 ± 3.9%, P = .046) followed by a decrease from low to peak dose (from −19.2 ± 3.9% to −17.5 ± 2.4%, P = .007) was observed. In addition, with regard to diagnostic accuracy in detecting CAD, WM yielded sensitivity of 44%, specificity of 55%, positive predictive value of 73%, and negative predictive value of 26%, whereas GLS, alternatively evaluated as the difference between peak dose and resting values or between peak and low-dose values, provided sensitivity of 61%, specificity of 90%, positive predictive value of 94%, and negative predictive value of 47% (respectively, P = .020, P = .001, P = .023, and P = .031, all vs WM) and sensitivity of 84%, specificity of 92%, positive predictive value of 96%, and negative predictive value of 68% (respectively, P < .001, P < .001, P = .001, P < .001, all vs WM).

Conclusions

GLS analysis, particularly performed by comparing peak-dose with low-dose values, improves the accuracy of dipyridamole stress echocardiography in the detection of single-vessel CAD compared with the sole assessment of WM changes.

Le texte complet de cet article est disponible en PDF.

Keywords : Dipyridamole, Stress echocardiography, Longitudinal strain, Coronary artery disease

Abbreviations : CAD, DipSE, GLS, LS, NPV, PPV, 2D, WM, WMSI


Plan


© 2015  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 28 - N° 10

P. 1214-1221 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Pericardiectomy is Associated with Improvement in Longitudinal Displacement of Left Ventricular Free Wall Due to Increased Counterclockwise Septal-to-Lateral Rotational Displacement
  • Kazuaki Negishi, Zoran B. Popovi?, Tomoko Negishi, Hirohiko Motoki, M. Chadi Alraies, Srisakul Chirakarnjanakorn, Arun Dahiya, Allan L. Klein
| Article suivant Article suivant
  • Novel Approach to Three-Dimensional Echocardiographic Quantification of Right Ventricular Volumes and Function from Focused Views
  • Diego Medvedofsky, Karima Addetia, Amit R. Patel, Anke Sedlmeier, Rolf Baumann, Victor Mor-Avi, Roberto M. Lang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.