S'abonner

Copper surfaces are associated with significantly lower concentrations of bacteria on selected surfaces within a pediatric intensive care unit - 23/01/16

Doi : 10.1016/j.ajic.2015.09.008 
Michael G. Schmidt, PhD a, ⁎ , Bettina von Dessauer, MD b, Carmen Benavente, MD b, Dona Benadof, MD c, Paulina Cifuentes, RN b, Alicia Elgueta, RN d, Claudia Duran, MS e, Maria S. Navarrete, MD, MPH f
a Department of Microbiology and Immunology, Medical University of South Carolina, Charleston, SC 
b Pediatric Intensive Care Unit, Hospital de Niños Roberto del Río, Santiago, Chile 
c Microbiology Laboratory, Hospital de Niños Roberto del Río, Santiago, Chile 
d Infection Control Committee, Hospital de Niños Roberto del Río, Santiago, Chile 
e Department of Microbiology, University of Chile, Santiago, Chile 
f School of Public Health, Faculty of Medicine, University of Chile, Santiago, Chile 

∗Address correspondence to Michael G. Schmidt, PhD, Department of Microbiology and Immunology, Medical University of South Carolina, 173 Ashley Ave, BSB 214A, Charleston, SC 29425-0504.

Abstract

Background

Health care–associated infections result in significant patient morbidity and mortality. Although cleaning can remove pathogens present on hospital surfaces, those surfaces may be inadequately cleaned or recontaminated within minutes. Because of copper’s inherent and continuous antimicrobial properties, copper surfaces offer a solution to complement cleaning. The objective of this study was to quantitatively assess the bacterial microbial burden coincident with an assessment of the ability of antimicrobial copper to limit the microbial burden associated with 3 surfaces in a pediatric intensive care unit.

Methods

A pragmatic trial was conducted enrolling 1,012 patients from 2 high acuity care units within a 249-bed tertiary care pediatric hospital over 12 months. The microbial burden was determined from 3 frequently encountered surfaces, regardless of room occupancy, twice monthly, from 16 rooms, 8 outfitted normally and 8 outfitted with antimicrobial copper.

Results

Copper surfaces were found to be equivalently antimicrobial in pediatric settings to activities reported for adult medical intensive care units. The log10 reduction to the microbial burden from antimicrobial copper surfaced bed rails was 1.996 (99%). Surprisingly, introduction of copper objects to 8 study rooms was found to suppress the microbial burden recovered from objects assessed in control rooms by log10 of 1.863 (73%).

Conclusion

Copper surfaces warrant serious consideration when contemplating the introduction of no-touch disinfection technologies for reducing burden to limit acquisition of HAIs.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

•
The built hospital environment serves as a tremendous and continuous reservoir of microbes capable of colonizing and infecting patients.
•
Cleaning, hand hygiene, and infection control bundles while effective cannot completely eliminate this risk.
•
Augmenting the built hospital environment with continuously active antimicrobial surfaces fabricated from U.S. Environmental Protection Agency–registered copper surfaces can significant lower the microbial burden, helping to augment existing infection control strategies.
•
Copper surfaces were found to be significantly effective in lowering the burden found in multibed rooms associated with pediatric intensive care units.
•
Copper surfaces warrant serious consideration when contemplating the introduction of no-touch disinfection technologies for reducing burden to limit acquisition of health care–associated infections.

Le texte complet de cet article est disponible en PDF.

Key Words : Antimicrobial copper, Environmental burden, Hospital-associated infection mitigation


Plan


 Funding/Support: This project was supported in part by the Ministry of Health of the Republic of Chile by investment funds for refurbishing the Intensive Care Unit of the Roberto del Río Hospital and the Corporación Nacional del Cobre de Chile through an unrestricted research grant administered by DUAM S.A.
 Disclaimer: The views, opinions, and/or findings presented here are those of the authors and should not be construed as an official policy of the government of Chile or Corporación Nacional del Cobre de Chile.
 Conflicts of Interest: None to report.


© 2016  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 44 - N° 2

P. 203-209 - février 2016 Retour au numéro
Article précédent Article précédent
  • Retrospective cohort study evaluating the incidence of diabetic foot infections among hospitalized adults with diabetes in the United States from 1996-2010
  • Bryson M. Duhon, Elizabeth O. Hand, Crystal K. Howell, Kelly R. Reveles
| Article suivant Article suivant
  • A bundle that includes active surveillance, contact precaution for carriers, and cefazolin-based antimicrobial prophylaxis prevents methicillin-resistant Staphylococcus aureus infections in clean orthopedic surgery
  • Hideki Kawamura, Kazuaki Matsumoto, Akari Shigemi, Michiyo Orita, Aya Nakagawa, Satoko Nozima, Hiroyuki Tominaga, Takao Setoguchi, Setsuro Komiya, Koichi Tokuda, Junichiro Nishi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.