Contained tissue extraction using power morcellation: prospective evaluation of leakage parameters - 04/02/16
, Stephanie N. Morris, MD c, Doug N. Brown, MD d, James A. Greenberg, MD e, Brian W. Walsh, MD b, Antonio R. Gargiulo, MD b, Keith B. Isaacson, MD c, Kelly N. Wright, MD f, Serene S. Srouji, MD b, Raymond M. Anchan, MD b, Alison B. Vogell, MD f, Jon I. Einarsson, MD, PhD, MPH aAbstract |
Background |
Safe tissue removal is a challenge for minimally invasive procedures such as myomectomy, supracervical hysterectomy, or total hysterectomy of a large uterine specimen. There is concern regarding disruption or dissemination of tissue during this process, which may be of particular significance in cases of undetected malignancy. Contained tissue extraction techniques have been developed in an effort to mitigate morcellation-related risks.
Objective |
The objective of the study was to quantify perioperative outcomes of contained tissue extraction using power morcellation, specifically evaluating parameters of tissue or fluid leakage from within the containment system.
Study Design |
This was a study including a multicenter prospective cohort of adult women who underwent minimally invasive hysterectomy or myomectomy using a contained power morcellation technique. Blue dye was applied to the tissue specimen prior to removal to help identify cases of fluid or tissue leakage from within the containment system.
Results |
A total of 76 patients successfully underwent the contained power morcellation protocol. Mean time for the contained morcellation procedure was 30.2 minutes (±22.4). The mean hysterectomy specimen weight was 480.1 g (±359.1), and mean myomectomy specimen weight was 239.1 g (±229.7). The vast majority of patients (73.7%) were discharged home the same day of surgery. Final pathological diagnosis was benign in all cases. Spillage of dye or tissue was noted in 7 cases (9.2%), although containment bags were intact in each of these instances.
Conclusion |
Findings are consistent with prior work demonstrating the feasibility of contained tissue extraction; however, further refinement of this technique is warranted.
Le texte complet de cet article est disponible en PDF.Key words : hysterectomy, in-bag morcellation, laparoscopic surgery, myomectomy
Plan
| R.M.A. receives support from Patient-Centered Outcomes Research Institute (PCORI) and the Agency for Healthcare Research and Quality (AHRQ) Comparing Options for Management: Patient-Centered Results for Uterine Fibroids (COMPARE UF) K.B.I. is a consultant for Karl Storz Endoscopy. The other authors report no conflict of interest. |
|
| Cite this article as: Cohen SL, Morris SN, Brown DN, et al. Contained tissue extraction using power morcellation: prospective evaluation of leakage parameters. Am J Obstet Gynecol 2016;214:257.e1-6. |