S'abonner

Extubating Extremely Preterm Infants: Predictors of Success and Outcomes following Failure - 25/05/16

Doi : 10.1016/j.jpeds.2016.02.016 
Brett J. Manley, PhD 1, 2, , Lex W. Doyle, MD 1, 2, 3, 4, Louise S. Owen, MD 1, 2, 4, Peter G. Davis, MD 1, 2, 4
1 Newborn Research Center and Neonatal Services, The Royal Women's Hospital, Parkville, Victoria, Australia 
2 Department of Obstetrics and Gynecology, The University of Melbourne, Parkville, Victoria, Australia 
3 Department of Pediatrics, The University of Melbourne, Parkville, Victoria, Australia 
4 Murdoch Childrens Research Centre, Parkville, Victoria, Australia 

Reprint requests: Brett J. Manley, PhD, Newborn Research Center and Neonatal Services, The Royal Women's Hospital, Level 7, 20 Flemington Rd, Parkville, Victoria 3052, Australia.Newborn Research Center and Neonatal ServicesThe Royal Women's HospitalLevel 7, 20 Flemington RdParkvilleVictoria3052Australia

Abstract

Objectives

To identify variables that predict extubation success in extremely preterm infants born <28 weeks gestational age (GA), and to compare outcomes between those who had successful or failed extubation.

Study design

A secondary analysis of data from a randomized trial of postextubation respiratory support that included 174 extremely preterm infants. “Extubation success” was defined as not requiring reintubation within 7 days, and “extubation failure” the converse. Predictive variables that were different between groups were included in a multivariable logistic regression model.

Results

Sixty-eight percent of infants were successfully extubated. Compared with those infants who had extubation failure, they had a higher GA and birth weight, were extubated earlier, were more often exposed to prolonged ruptured membranes, more often avoided intubation in the delivery room, had a higher pre-extubation pH, and had lower mean pre-extubation fraction of inspired oxygen and partial pressure of carbon dioxide (PCO2). Only GA and PCO2 remained significant in the multivariable analysis (area under a receiver operating characteristic curve = 0.81). Extubation failure was associated with death, bronchopulmonary dysplasia, severe retinopathy of prematurity, patent ductus arteriosus ligation, and longer durations of respiratory support, oxygen supplementation, and hospitalization. When adjusted for allocated treatment in the randomized trial, GA, and birth weight z-score, extubation failure remained associated with death before discharge and prolonged respiratory support and hospitalization.

Conclusions

In extremely preterm infants, higher GA and lower pre-extubation PCO2 predicted extubation success. Infants in whom extubation failed were more likely to die and have prolonged respiratory support and hospitalization.

Trial registration

Australian New Zealand Clinical Trials Network: ACTRN12610000166077.

Le texte complet de cet article est disponible en PDF.

Keywords : Mechanical ventilation, Neonatal intensive care

Abbreviations : BPD, CPAP, FiO2, GA, HFNC, PCO2


Plan


 Funded by the National Health and Medical Research Council (606789). The authors declare no conflicts of interest.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 173

P. 45-49 - juin 2016 Retour au numéro
Article précédent Article précédent
  • Risk Factors and In-Hospital Outcomes following Tracheostomy in Infants
  • Jan Hau Lee, P. Brian Smith, M. Bin Huey Quek, Matthew M. Laughon, Reese H. Clark, Christoph P. Hornik
| Article suivant Article suivant
  • High Flow Nasal Cannula Use Is Associated with Increased Morbidity and Length of Hospitalization in Extremely Low Birth Weight Infants
  • Dalal K. Taha, Michael Kornhauser, Jay S. Greenspan, Kevin C. Dysart, Zubair H. Aghai

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.