S'abonner

Outer Retinal Structural Alternation and Segmentation Errors in Optical Coherence Tomography Imaging in Patients With a History of Retinopathy of Prematurity - 26/05/16

Doi : 10.1016/j.ajo.2016.03.030 
Yi-Hsing Chen a, c, Reyin Lien b, c, Michael F. Chiang d, Chung-Ying Huang a, c, Chee-Jen Chang e, Nan-Kai Wang a, c, Yen-Po Chen a, c, An-Ning Chao a, c, Kuan-Jen Chen a, c, Tun-Lu Chen a, c, Yih-Shiou Hwang a, c, Chi-Chun Lai a, c, Wei-Chi Wu a, c,
a Department of Ophthalmology, Chang Gung Memorial Hospital, Taoyuan, Taiwan 
b Department of Pediatrics, Chang Gung Memorial Hospital, Taoyuan, Taiwan 
c College of Medicine, Chang Gung University, Taoyuan, Taiwan 
d Departments of Ophthalmology and Medical Informatics & Clinical Epidemiology, Casey Eye Institute, Oregon Health & Science University, Portland, Oregon 
e Graduate Institute of Clinical Medical Science, Chang Gung University, Taoyuan, Taiwan 

Inquiries to Wei-Chi Wu, Department of Ophthalmology, Chang Gung Memorial Hospital, No. 5, Fu-Hsin Rd, Taoyuan, Taiwan 333Department of OphthalmologyChang Gung Memorial HospitalNo. 5, Fu-Hsin RdTaoyuan333Taiwan

Abstract

Purpose

To evaluate retinal anatomy and segmentation errors from spectral-domain optical coherence tomography (SD-OCT) imaging in school-aged children.

Design

A prospective cohort study in a referral medical center.

Methods

One hundred thirty-three eyes of 133 patients were enrolled. Patients were grouped as those who were treated for retinopathy of prematurity (ROP) (ROP-Tx group); those with spontaneously regressed ROP (ROP-non-Tx group); other premature patients (premature group); and full-term age-matched children (full-term group). Anatomy and segmentation errors of retina were evaluated by SD-OCT.

Results

The mean age at assessment was 9.5 years (range, 4–16 years). The external limiting membrane (ELM) and the cone outer segment tips (COST) line were least frequently identified in patients of the ROP-Tx group (65.2% and 47.8%, P = .002 and P < .001, respectively). The visual acuity of the patients did not correlate significantly with the absence of COST line (P = .140) but correlated with the absence of ELM (P < .001). The presence of artifacts, including misidentification of the inner retina, misidentification of the outer retina, out-of-register artifacts, off-center scans, and degraded scan images, was observed to range from 0.6% to 50.0% in 4 groups of patients. All types of errors occurred more frequently in the ROP-Tx group than in the full-term group (all P < .05).

Conclusions

Outer retinal abnormalities were commonly observed in the ROP-Tx group. The higher segmentation errors in the ROP-Tx group might be related to fine structural abnormalities in the outer retina. Future studies are needed to investigate the mechanisms for these structural changes.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 166

P. 169-180 - juin 2016 Retour au numéro
Article précédent Article précédent
  • Ocular Toxocariasis: Clinical Features and Long-term Visual Outcomes in Adult Patients
  • Raphaelle Despreaux, Christine Fardeau, Sara Touhami, Emmanuelle Brasnu, Emmanuelle Champion, Luc Paris, Valérie Touitou, Bahram Bodaghi, Phuc Lehoang
| Article suivant Article suivant
  • Tumor Volumes in Choroidal Melanoma: Agreement Between Three-Dimensional Ultrasound and Two Mathematical Models
  • Josep M. Caminal, Karol Mejía, Luis Arias, Cristina Masuet-Aumatell, Jon Larrucea-Maseda, Ignasi Modolell, Daniel Lorenzo, Jaume Català, Marc Rubio, Estefanía Cobos, Pere Garcia-Bru, Ignacio Flores, Alejandro Filloy, Jordi Arruga

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.