S'abonner

Prospective multicenter study on the usefulness of EUS-guided FNA biopsy for the diagnosis of autoimmune pancreatitis - 16/07/16

Doi : 10.1016/j.gie.2016.01.016 
Tomomasa Morishima, MD 1, Hiroki Kawashima, MD, PhD 1, Eizaburo Ohno, MD, PhD 1, Takeshi Yamamura, MD, PhD 2, Kohei Funasaka, MD, PhD 2, Masanao Nakamura, MD, PhD 1, Ryoji Miyahara, MD, PhD 1, Osamu Watanabe, MD, PhD 1, Masatoshi Ishigami, MD, PhD 1, Yoshie Shimoyama, MD, PhD 3, Shigeo Nakamura, MD, PhD 3, Senju Hashimoto, MD, PhD 4, Hidemi Goto, MD, PhD 1, Yoshiki Hirooka, MD, PhD 2,
1 Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan 
2 Department of Endoscopy, Nagoya, Japan 
3 Nagoya University Hospital Department of Pathology and Laboratory Medicine, Nagoya, Japan 
4 Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University, Toyoake, Japan 

Reprint requests: Yoshiki Hirooka, Department of Endoscopy, Nagoya University Hospital, Nagoya, Japan Tsuruma-Cho, Showa-ku, Nagoya City, 466-8550, Japan.Department of EndoscopyNagoya University HospitalNagoya, Japan Tsuruma-ChoShowa-kuNagoya City, 466-8550Japan

Abstract

Background and Aims

In the International Consensus Diagnostic Criteria (ICDC), autoimmune pancreatitis (AIP) is classified into types 1 and 2, and its definite histopathology diagnosis can be made based only on surgical or core biopsy specimens. Although EUS-guided FNA (EUS-FNA) biopsy is a safe technique for the collection of pancreatic tissue, no consensus viewpoint has been reached with regard to the role of EUS-FNA biopsy in the diagnosis of AIP. This study investigated the utility of pancreatic tissue collected by EUS-FNA biopsy by using a standard 22-gauge aspiration needle in the diagnosis of AIP.

Methods

Patients with suspected AIP were prospectively enrolled in Nagoya University Hospital and Nagoya University–affiliated institutions. Pancreatic tissue was collected from each by EUS-FNA biopsy with a standard 22-gauge aspiration needle.

Results

Fifty patients were registered, including 45 with a final diagnosis of AIP. Lymphoplasmacytic infiltration and abundant immunoglobulin G4–positive plasmacyte infiltration (>10/high-power field) were detected in 36 (72%) and 27 (54%) patients, respectively. Obliterative phlebitis and storiform fibrosis were not detected in our study. Granulocytic epithelial lesions (GEL) were observed in 3 patients. The sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNA biopsy to definitively diagnose AIP were 7.9% (3/38), 100% (12/12), 100% (3/3), and 25.5% (12/47), respectively. Pathology evaluation of pancreatic tissue collected by EUS-FNA biopsy improved the diagnostic accuracy in 8 (16%) of the 50 patients.

Conclusions

In this study, EUS-FNA biopsy by using a standard 22-gauge aspiration needle is not an effective diagnostic method for most patients with AIP. The combination of level 2 histology diagnosis of AIP with other findings specified in the ICDC slightly improved the diagnostic accuracy, although it still remains insufficiently accurate for routine clinical use.(Clinical trial registration number: 000006297.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : AIP, EUS-FNA, GEL, H&E, HPF, ICDC, IDCP, IgG, LPSP, NPV, PPV


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 See CME section; p. 329.


© 2016  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 84 - N° 2

P. 241-248 - août 2016 Retour au numéro
Article précédent Article précédent
  • Outcomes after endoscopic versus surgical therapy for early esophageal cancers in an older population
  • Linda C. Cummings, Tzuyung Doug Kou, Mark D. Schluchter, Amitabh Chak, Gregory S. Cooper
| Article suivant Article suivant
  • Fine-needle aspiration for autoimmune pancreatitis—not ready for prime time
  • Jeffrey M. Adler, Timothy B. Gardner

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.