S'abonner

Cutting Edge in Thyroid Surgery: Autofluorescence of Parathyroid Glands - 25/07/16

Doi : 10.1016/j.jamcollsurg.2016.04.049 
Jorge Falco, MD, FACS a, Fernando Dip, MD a, b, ⁎ , Pablo Quadri, MD a, Martin de la Fuente, MD a, Raul Rosenthal, MD, FACS b
a Hospital de Clínicas “José de San Martín”, University of Buenos Aires, Buenos Aires, Argentina 
b The Bariatric and Metabolic Institute, Section of Minimally Invasive Surgery, Department of General and Vascular Surgery, Cleveland Clinic Florida, Weston, FL 

∗Correspondence address: Fernando Dip, MD, Staff Surgical Oncology, Hospital de Clínicas “José de San Martín”, 2300 Cordoba Av, Buenos Aires Capital City, Zip Code: 1120, Argentina.Staff Surgical OncologyHospital de Clínicas “José de San Martín”2300 Cordoba AvBuenos Aires Capital CityZip Code: 1120Argentina

Abstract

Background

Identification of parathyroid glands may be challenging during thyroid and parathyroid surgery. Accidental resection of the glands may increase the morbidity of the surgery. The aim of this study was to evaluate accuracy in identification of autofluorescent parathyroid glands with the use of near infrared light in real time.

Study Design

Patients undergoing thyroid and parathyroid surgery between June and August 2015 were included in the study. During the procedure, the surgical field was exposed to near infrared laser light in order to analyze the intensity of the fluorescence of different tissues (parathyroid glands, thyroid glands, and background). Surgical images were recorded and analyzed.

Results

Twenty-eight patients were included in the study. Nineteen patients were women and 9 were men. Seven patients had primary hyperparathyroidism, 4 had hyperthyroidism, 3 had goiters, and 11 had thyroid cancer. Three patients had mixed pathologies, including 2 patients with thyroid cancer and primary hyperparathyroidism and 1 patient with goiter and primary hyperparathyroidism. Identification of autofluorescent parathyroid glands was achieved in all patients with near infrared light.

The mean fluorescent intensity of parathyroid glands was 40.6 (±26.5), thyroid glands 31.8 (±22.3), and background 16.6 (±15.4). Parathyroid glands demonstrated statistically higher fluorescence intensity compared with the thyroid gland and background (p < 0.0014). No postoperative hypocalcemia or other complications related to the surgery were registered.

Conclusions

Visualization of autofluorescent parathyroid glands with the use of near infrared light allows high rates of parathyroid gland identification and could be a safe, feasible, and noninvasive method for intraoperative identification of parathyroid glands in real time. Further clinical studies must be performed to determine the cost-effectiveness and clinical application of this method.

Le texte complet de cet article est disponible en PDF.

Plan


 Disclosure Information: Equipment used in this study was provided by Fluoptics. The authors have nothing further to disclose.


© 2016  American College of Surgeons. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 223 - N° 2

P. 374-380 - août 2016 Retour au numéro
Article précédent Article précédent
  • Comparison of 30-Day Postoperative Outcomes after Laparoscopic vs Robotic Colectomy
  • Peter E. Miller, Haisar Dao, Nivedh Paluvoi, Matthew Bailey, David Margolin, Nishit Shah, H.D. Vargas
| Article suivant Article suivant
  • Preoperative Myocardial Injury as a Predictor of Mortality in Emergency General Surgery: An Analysis Using the American College of Surgeons NSQIP Database
  • Asha M. Zimmerman, Jayson Marwaha, Hector Nunez, David Harrington, Daithi Heffernan, Sean Monaghan, Charles Adams, Andrew Stephen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.