S'abonner

Improving the diagnostic yield of single-operator cholangioscopy-guided biopsy of indeterminate biliary strictures: ROSE to the rescue? (with video) - 14/09/16

Doi : 10.1016/j.gie.2016.03.1497 
Shyam Varadarajulu, MD 1, , Ji Young Bang, MD, MPH 2, , Muhammad K. Hasan, MD 1, Udayakumar Navaneethan, MD 1, Robert Hawes, MD 1, Shantel Hebert-Magee, MD 1
1 Center for Interventional Endoscopy, Florida Hospital, Orlando, Florida, USA 
2 Divison of Gastroenterology-Hepatology, Indiana University, Indianapolis, Indiana, USA 

Reprint requests: Shyam Varadarajulu, MD, Medical Director, Center for Interventional Endoscopy, Florida Hospital, 601 East Rollins Street, Orlando, FL 32803.Center for Interventional Endoscopy, Florida Hospital601 East Rollins StreetOrlandoFL 32803

Abstract

Background and Aims

Tissue diagnosis, regardless of technique or endoscope used, can be challenging in patients with indeterminate biliary strictures (IDBSs). This exploratory study evaluated the utility and role of rapid onsite evaluation of touch imprint cytology (ROSE-TIC) when single-operator cholangioscopy (SOC)-guided biopsies of IDBSs are performed.

Methods

Patients with IDBSs were evaluated by intraprocedural ROSE-TIC during SOC-guided biopsy procedures. Final diagnosis was established by long-term patient follow-up in conjunction with off-site findings or surgical histology. The main outcome measure was to evaluate the utility of ROSE-TIC by determination of its operating characteristics and comparison with off-site histologic assessment.

Results

Of 31 patients with IDBSs, tissue diagnosis was indeterminate at prior ERCP-guided brush and/or biopsy in 14, prior EUS-guided FNA (EUS-FNA) in 6, and a mass could not be identified at EUS in 11. The mean number of biopsies performed was 3.3 (range 1-8), and diagnostic interpretation by ROSE-TIC was diagnostic and/or suspicious for carcinoma in 15, benign in 13, atypical-reactive in 2, and bile duct intraductal papillary mucinous neoplasm in 1. Final diagnosis by surgical histology (n = 4), death by disease (n = 10), and patient follow-up (n = 17) showed that the overall sensitivity of ROSE-TIC for diagnosing malignancy was 100%, specificity 88.9%, positive predictive value 86.7%, negative predictive value 100%, and diagnostic accuracy 93.5%.

Conclusions

Preliminary data suggest that the diagnostic outcomes of SOC-guided biopsies in IDBSs can be significantly improved by using ROSE-TIC. This technique also may benefit centers that rely mainly on fluoroscopy-guided intraductal biopsies.

Le texte complet de cet article est disponible en PDF.

Abbreviations : CBD, EUS-FNA, H&E, IDBS, IPMN, PSC, ROSE, SOC, TIC


Plan


 DISCLOSURE: S. Varadarajulu and R. Hawes are consultants for Olympus Medical Systems and Boston Scientific. J. Bang is a consultant for Olympus Medical Systems. S. Hebert-Magee is a consultant for Boston Scientific. All other authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Varadarajulu at svaradarajulu@yahoo.com.
 See CME section; p. 717.


© 2016  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 84 - N° 4

P. 681-687 - octobre 2016 Retour au numéro
Article précédent Article précédent
  • Wanted: improved diagnostic accuracy or tissue for histology by EUS-FNA. Do side-holes do the job?
  • John Gásdal Karstensen, Peter Vilmann
| Article suivant Article suivant
  • Endoscopic mucosal resection of large and giant lateral spreading lesions of the duodenum: success, adverse events, and long-term outcomes
  • Amir Klein, Dhruv Nayyar, Farzan F. Bahin, Zhengyan Qi, Eric Lee, Stephen J. Williams, Karen Byth, Michael J. Bourke

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.