S'abonner

Awake tracheal intubation in anticipated difficult airways: LMA Fastrach vs flexible bronchoscope: A pilot study - 18/04/17

Doi : 10.1016/j.jclinane.2016.10.040 
Sherine F. Hanna, MD a, ⁎  : (Associate Professor), Marianne Mikat-Stevens, MD a : (Associate Professor), James Loo, MD a : (Associate Professor), Raj Uppal, MD b : (Chief), W. Scott Jellish, MD, PHD a : (Professor and Chairman), Matthew Adams c : (Medical Student)
a Department of Anesthesiology, Loyola University Medical Center/Stritch School of Medicine, Maywood, IL 60153, USA 
b Department of Anesthesiology, VA Hines Medical Center, Hines, IL 60141, USA 
c American University of Antigua Medical School, New York, NY 10004, USA 

⁎Corresponding author at: Sherine F. Hanna, MD, Department of Anesthesiology, Loyola University Medical Center, Maywood, IL 60153, USA. Tel.: +630 479 64 45Department of AnesthesiologyLoyola University Medical CenterMaywoodIL60153USA

Abstract

Study objective

To compare the use of LMA Fastrach intubating laryngeal mask airway (ILMA) to flexible bronchoscopy (FB) for awake intubation in patients with difficult airways.

Design

Randomized prospective study.

Setting

Large academic medical center.

Patients

Forty adult patients, American Society of Anesthesiologists I-IV, meeting the criteria for awake intubation based on history and physical examination.

Interventions

After sedation and airway topicalization, patients were randomized to either FB group, n=19, or ILMA group, n=21. All intubations were performed by or under the supervision of an attending anesthesiologists, with variable participation of residents or certified registered nurse anesthetists. A maximum of three attempts were permitted with the assigned technique, to be followed by the alternative method in case of failure.

Measurements

Times to carbon dioxide (end-tidal carbon dioxide) detection, endotracheal tube placement, number of attempts, training level of operator, and adverse events were recorded. Blood pressure, oxygen saturation, and heart rate were measured. Patients were interviewed the following day regarding their experience and satisfaction.

Main results

Overall intubation success rate within three attempts was 95% for both groups. However, successful intubation on the first attempt occurred at a significantly higher rate with ILMA vs FB (95% vs 58%; P=.0028). Total mean time to endotracheal tube placement was also significantly shorter in the ILMA group vs FB (92 vs 246 seconds; P=.0001). There were no adverse events in either group, and patient satisfaction was not significantly different.

Conclusion

Awake intubation can be performed successfully and expeditiously with the use of LMA Fastrach in patients with a difficult airway and no contraindication to a blind technique. It compared favorably to the use of the fiberoptic bronchoscope in the patient cohort presented in this study.

Le texte complet de cet article est disponible en PDF.

Highlights

•
Forty patients needing awake intubation were randomized to ILMA or FB group.
•
Intubations were performed by or under the supervision of an attending anesthesiologist.
•
Time to carbon dioxide, number of attempts, vital signs, and patient satisfaction were compared.
•
Intubation success rate within three attempts was 95% for both groups.
•
First attempt success was significantly higher in the ILMA group (95% vs 58%).

Le texte complet de cet article est disponible en PDF.

Keywords : Awake fastrach intubation, Difficult airway management, Awake intubation, Fastrach intubation in comparison with fiberoptic bronchoscope, Anticipated difficult airway, Awake Intubation, Airway management, Intubation techniques


Plan


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 37

P. 31-37 - février 2017 Retour au numéro
Article précédent Article précédent
  • Fast-track anesthesia in patients undergoing outpatient laparoscopic cholecystectomy: comparison of sevoflurane with total intravenous anesthesia
  • Ceyda Özhan Çaparlar, Mehmet Özgür Özhan, Mehmet An?l Süzer, Dilek Yazicio?lu, Mehmet Burak E?kin, Serkan ?enkal, Mehmet Ali Çaparlar, Ersin Özkan Imren, Bülent Atik, Nedim Çekmen
| Article suivant Article suivant
  • Cardiac output changes with phenylephrine and ephedrine infusions during spinal anesthesia for cesarean section: A randomized, double-blind trial
  • W. Mon, A. Stewart, R. Fernando, K. Ashpole, N. El-Wahab, S MacDonald, P. Tamilselvan, M. Columb, Y.M. Liu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.