S'abonner

Needle-based confocal laser endomicroscopy for the diagnosis of pancreatic cystic lesions: an international external interobserver and intraobserver study (with videos) - 14/09/17

Doi : 10.1016/j.gie.2017.03.002 
Somashekar G. Krishna, MD, MPH 1, , William R. Brugge, MD, MPH 2, John M. Dewitt, MD 3, Pradermchai Kongkam, MD 4, Bertrand Napoleon, MD 5, Carlos Robles-Medranda, MD 6, Damien Tan, MBBS 7, Samer El-Dika, MD 1, Sean McCarthy, MD 1, Jon Walker, MD, MS 1, Mary E. Dillhoff, MD, MS 8, Andrei Manilchuk, MD 9, Carl Schmidt, MD 8, Benjamin Swanson, MD 10, Zarine K. Shah, MD 11, Phil A. Hart, MD 1, Darwin L. Conwell, MD, MS 1
1 Division of Gastroenterology, Hepatology and Nutrition, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA 
2 Pancreas Biliary Center, Gastrointestinal Unit, Massachusetts General Hospital, Boston, Massachusetts, USA 
3 Division of Gastroenterology, Department of Medicine, Indiana University Hospital, Indianapolis, Indiana, USA 
4 Department of Medicine, Faculty of Medicine, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Bangkok, Thailand 
5 Department of Gastroenterology, Ramsay Générale de Santé, Hôpital privé Jean Mermoz, Lyon, France 
6 Gastroenterology and Endoscopy Division, Instituto Ecuatoriano de Enfermedades Digestivas, University Hospital OMNI, Guayaquil, Ecuador 
7 Department of Gastroenterology and Hepatology, Singapore General Hospital, Singapore 
8 Division of Surgical Oncology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA 
9 Department of General Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA 
10 Department of Pathology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA 
11 Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA 

Reprint requests: Dr Somashekar G. Krishna, 395 W. 12th Avenue, Suite 262, Division of Gastroenterology, Hepatology and Nutrition, Columbus, Ohio, USA.395 W. 12th Avenue, Suite 262Division of GastroenterologyHepatology and NutritionColumbusOhioUSA

Abstract

Background and Aims

EUS-guided needle-based confocal laser endomicroscopy (nCLE) characteristics of common types of pancreatic cystic lesions (PCLs) have been identified; however, surgical histopathology was available in a minority of cases. We sought to assess the performance characteristics of EUS nCLE for differentiating mucinous from non-mucinous PCLs in a larger series of patients with a definitive diagnosis.

Methods

Six endosonographers (nCLE experience >30 cases each) blinded to all clinical data, reviewed nCLE images of PCLs from 29 patients with surgical (n = 23) or clinical (n = 6) correlation. After 2 weeks, the assessors reviewed the same images in a different sequence. A tutorial on available and novel nCLE image patterns was provided before each review. The performance characteristics of nCLE and the κ statistic for interobserver agreement (IOA, 95% confidence interval [CI]), and intraobserver reliability (IOR, mean ± standard deviation [SD]) for identification of nCLE image patterns were calculated. Landis and Koch interpretation of κ values was used.

Results

A total of 29 (16 mucinous PCLs, 13 non-mucinous PCLs) nCLE patient videos were reviewed. The overall sensitivity, specificity, and accuracy for the diagnosis of mucinous PCLs were 95%, 94%, and 95%, respectively. The IOA and IOR (mean ± SD) were κ = 0.81 (almost perfect); 95% CI, 0.71-0.90; and κ = 0.86 ± 0.11 (almost perfect), respectively. The overall specificity, sensitivity, and accuracy for the diagnosis of serous cystadenomas (SCAs) were 99%, 98%, and 98%, respectively. The IOA and IOR (mean ± SD) for recognizing the characteristic image pattern of SCA were κ = 0.83 (almost perfect); 95% CI, 0.73-0.92; and κ = 0.85 ± 0.11 (almost perfect), respectively.

Conclusions

EUS-guided nCLE can provide virtual histology of PCLs with a high degree of accuracy and inter- and intraobserver agreement in differentiating mucinous versus non-mucinous PCLs. These preliminary results support larger multicenter studies to evaluate EUS nCLE. (Clinical trial registration number: NCT02516488.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : CEA, CI, CLE, HGD, IOA, IOR, IPMN, IV, MCN, MRI, nCLE, NET, PCL, SCA, SD


Plan


 DISCLOSURE: This study was funded in part by theAmerican College of Gastroenterology pilot researchgrant (S.K.). All other authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Krishna at sgkrishna@gmail.com.


© 2017  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 86 - N° 4

P. 644 - octobre 2017 Retour au numéro
Article précédent Article précédent
  • EUS-guided gallbladder drainage in patients with acute cholecystitis and high surgical risk using an electrocautery-enhanced lumen-apposing metal stent device
  • Markus Dollhopf, Alberto Larghi, Uwe Will, Mihai Rimba?, Andrea Anderloni, Andres Sanchez-Yague, Anthony Yuen Bun Teoh, Rastislav Kunda
| Article suivant Article suivant
  • EUS-guided celiac ganglia neurolysis: a clinical and human cadaver study (with video)
  • Wouter F.W. Kappelle, Ronald L.A.W. Bleys, Albert J.M. van Wijck, Peter D. Siersema, Frank P. Vleggaar

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.