S'abonner

Linked-color imaging improves endoscopic visibility of colorectal nongranular flat lesions - 14/09/17

Doi : 10.1016/j.gie.2017.01.044 
Takuto Suzuki, PhD, MD 1, , Taro Hara, PhD, MD 2, Yoshiyasu Kitagawa, MD 1, Hideyuki Takashiro, MD 3, Rino Nankinzan, MD 3, Osamu Sugita, MD 3, Taketo Yamaguchi, PhD, MD 3
1 Department of Endoscopy, Chiba Cancer Center, Chuoku, Chiba, Japan 
2 Hara Clinic, Chuoku, Chiba, Japan 
3 Department of Gastroenterology, Chiba Cancer Center, Chuoku, Chiba, Japan 

Reprint requests: Dr Takuto Suzuki, Chiba Cancer Center, Nitonachou 666-2, Chuoku, Chiba 2608717, Japan.Chiba Cancer CenterNitonachou 666-2ChuokuChiba 2608717Japan

Abstract

Background and Aims

As a newly developed image-enhanced endoscopy (IEE) technique, linked-color imaging (LCI) provides very bright images with enhanced color tones. With the objective of improving the detection rate of colorectal flat tumor lesions, which are difficult to detect, we examined the usefulness of LCI from the viewpoint of visibility.

Methods

Fifty-three consecutive nongranular flat tumors were used in this study. Endoscopic images were acquired by white-light imaging (WLI), blue-laser imaging (BLI)–bright, and LCI modes. For each lesion, we selected 1 image each acquired by WLI, BLI-bright, and LCI modes. Six endoscopists interpreted the images. By using a previously reported visibility scale, we scored the visibility level on a scale of 1 to 4.

Results

The mean (± standard deviation) visibility scores were 2.74 ± 1.08 for WLI, 2.94 ± 0.97 for BLI-bright, and 3.36 ± 0.72 for LCI. The score was significantly higher for BLI-bright compared with WLI (P < .001) and again higher for LCI compared with BLI-bright (P < .001). When we compared between experts and trainees, the corresponding scores of experts were 2.83 ± 1.06, 3.17 ± 0.88, and 3.40 ± 0.74, with a tendency similar to the scores of all endoscopists. For the trainees, there was no difference between the scores for WLI (2.65 ± 1.10) and BLI-bright (2.71 ± 1.00), but the score for LCI (3.31 ± 0.69) was significantly higher than that for WLI or BLI-bright (P < .001). When only sessile serrated adenoma/polyp lesions were analyzed, LCI remained significantly higher than the other 2.

Conclusions

The present findings suggest that LCI increases the visibility of colorectal flat lesions and contributes to improvement of the detection rate for these lesions.

Le texte complet de cet article est disponible en PDF.

Abbreviations : BLI, IEE, LCI, SSA/P, WLI


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2017  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 86 - N° 4

P. 692-697 - octobre 2017 Retour au numéro
Article précédent Article précédent
  • Family history in colonoscopy patients: feasibility and performance of electronic and paper-based surveys for colorectal cancer risk assessment in the outpatient setting
  • Tannaz Guivatchian, Erika S. Koeppe, Jason R. Baker, Cristina Moisa, Matthew Demerath, Caitlin Foor-Pessin, William D. Chey, Shanti L. Eswaran, Joseph C. Kolars, Stacy B. Menees, Michael Rajala, Michael D. Rice, Rafat Rizk, Joel H. Rubenstein, Pratima Sharma, Andrea Todisco, Elena M. Stoffel
| Article suivant Article suivant
  • Image-enhanced endoscopy: How far do we need to go?
  • Hazem Hammad, Tonya Kaltenbach, Roy Soetikno

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.