S'abonner

Functional Cardiac Recovery and Hematologic Response to Chemotherapy in Patients With Light-Chain Amyloidosis (from the Stanford University Amyloidosis Registry) - 23/09/17

Doi : 10.1016/j.amjcard.2017.07.025 
Mirela Tuzovic, MD a, 1, * , Yukari Kobayashi, MD a, 1, Matthew Wheeler, MD, PhD a, Christopher Barrett, MD a, Michaela Liedtke, MD b, Richard Lafayette, MD c, Stanley Schrier, MD b, Francois Haddad, MD a, 2, Ronald Witteles, MD a, 2
a Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California 
b Division of Hematology, Stanford University School of Medicine, Stanford, California 
c Division of Nephrology, Stanford University School of Medicine, Stanford, California 

*Corresponding author: Tel: +1 310 206 6286; fax: +1 310 206 9133.

Abstract

Cardiac involvement is common in patients with light-chain (AL) amyloidosis and portends a poor prognosis, although little is known about the changes in cardiac mechanics after chemotherapy. We sought to explore the relation between amyloidosis staging and baseline cardiac mechanics and to investigate short-term changes in cardiac mechanics after chemotherapy. We identified 41 consecutive patients from the Stanford Amyloid Center who had echocardiograms and free light-chain values before and after chemotherapy, along with 40 age- and gender-matched controls. Echocardiographic assessment included left ventricular global longitudinal strain, E/e' ratio, and left atrial (LA) stiffness. Hematologic response to chemotherapy was defined as ≥50% reduction in the difference between the involved and the uninvolved free light chain (dFLC). The mean age was 66.9 ± 8.4 years and 66% were men. Before chemotherapy, global longitudinal strain, E/e' ratio, and LA stiffness were impaired in patients with amyloidosis compared with controls, and the severity of impairment worsened with advanced staging. After chemotherapy, hematologic response was observed in 30 (73%) patients. There was a significant association between the change in dFLC and cardiac function (E/e' ratio: r = −0.43, p = 0.01; LA stiffness: r = −0.35, p = 0.05). There was no significant improvement in cardiac mechanics in patients without a hematologic response to chemotherapy. In conclusion, amyloidosis stage correlated with noninvasive measurements of cardiac mechanics, and improvement in dFLC correlated with cardiac improvement on short-term follow-up echocardiography.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 1386 for disclosure information.


© 2017  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 120 - N° 8

P. 1381-1386 - octobre 2017 Retour au numéro
Article précédent Article précédent
  • Usefulness of Mitral Valve Prosthetic or Bioprosthetic Time Velocity Index Ratio to Detect Prosthetic or Bioprosthetic Mitral Valve Dysfunction
  • Sushil Allen Luis, Lori A. Blauwet, Himabindu Samardhi, Cathy West, Ramila A. Mehta, Chris R. Luis, Gregory M. Scalia, Fletcher A. Miller, Darryl J. Burstow
| Article suivant Article suivant
  • Patient Selection Process for the Harmony Transcatheter Pulmonary Valve Early Feasibility Study
  • Matthew J. Gillespie, Lee N. Benson, Lisa Bergersen, Emile A. Bacha, Sharon L. Cheatham, Andrew M. Crean, Andreas Eicken, Peter Ewert, Tal Geva, William E. Hellenbrand, Kan N. Hor, Eric M. Horlick, Thomas K. Jones, John Mayer, Brian T. McHenry, Mark D. Osten, Andrew J. Powell, Evan M. Zahn, John P. Cheatham

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.