S'abonner

Twenty-Year Experience with Aorto-Enteric Fistula Repair: Gastrointestinal Complications Predict Mortality - 06/10/17

Doi : 10.1016/j.jamcollsurg.2017.01.050 
Atish Chopra, MD a, Lucyna Cieciura, MD b, J Gregory Modrall, MD, FACS b, R James Valentine, MD, FACS c, Jayer Chung, MD, MSc, FACS d,
a Division of Vascular Surgery, Oregon Health and Science University, Portland, OR 
b Division of Vascular Surgery, University of Texas Southwestern Medical Center, Dallas, TX 
c Division of Vascular Surgery, Vanderbilt University Medical Center, Nashville, TN 
d Division of Vascular Surgery and Endovascular Therapy, Baylor College of Medicine, Houston, TX 

Correspondence address: Jayer Chung, MD, MSc, FACS, Division of Vascular Surgery and Endovascular Therapy, Michael E DeBakey Department of Surgery, Baylor College of Medicine, One Baylor Plaza, BCM 390, Houston, TX 76030.Division of Vascular Surgery and Endovascular TherapyMichael E DeBakey Department of SurgeryBaylor College of MedicineOne Baylor PlazaBCM 390HoustonTX76030

Abstract

Background

Aorto-enteric fistulas (AEF) represent a lethal subset of aortic graft infections. The optimal management of AEF remains unclear. We aimed to identify predictors of morbidity and mortality.

Study Design

We performed a single-center retrospective review of consecutive AEF repairs. Demographics, comorbidities, and perioperative variables were obtained. Descriptive statistics, chi-square, Kruskall-Wallis, and Cox proportional-hazards modeling were used where appropriate.

Results

Between June 1995 and October 2014, 50 patients (30 male; 60%) presented with AEF, with a median age of 70 years (interquartile range [IQR] 61 to 75 years). Median follow-up for the entire cohort was 14 months (IQR 5 to 27 months). Thirty-four (68%) subjects underwent aortic reconstruction with femoral vein; 12 (24%) with extra-anatomic bypass and aortic ligation; 3 (6%) with rifampin-soaked Dacron graft; and 1 (2%) with cryopreserved aortic allograft. The duodenum was the most common location of the enteric defect (n = 40, 80%). Duodenal leak complicated 6 (12%) of the primary enteric repairs, but none of the complex enteric repairs performed with resection and/or bypass. Twenty-three patients (46%) died by 60 days. Advanced age, chronic renal insufficiency, any complications, and gastrointestinal (GI) complications (n = 13, 26%) were all associated with an increase in overall mortality on univariate analysis (p < 0.05). Gastrointestinal complications (hazard ratio [HR] 3.23; 95% CI 1.27 to 8.25; p = 0.015) and advanced age (HR 1.07; 95% CI 1.01 to 1.13; p = 0.01) were the only independent predictors of mortality on multivariable regression models.

Conclusions

Over 20 years, approximately 50% of patients with AEF repairs died within 60 days. Gastrointestinal complications increase the risk of mortality more than 3-fold, representing an attractive surgically modifiable risk factor. Future multicenter studies are required to clarify optimal methods of arterial and GI reconstruction in AEF.

Le texte complet de cet article est disponible en PDF.

Abbreviations and Acronyms : AAA, AEF, EAB, EGD, EVAR, GI, HR, IQR, LOS, NAIS


Plan


 CME questions for this article available at jacscme.facs.org
 Disclosure Information: Authors have nothing to disclose. Timothy J Eberlein, Editor-in-Chief, has nothing to disclose.


© 2017  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 225 - N° 1

P. 9-18 - juillet 2017 Retour au numéro
Article précédent Article précédent
  • The Hidden Cost of Medicine
  • R James Valentine
| Article suivant Article suivant
  • Discussion

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.