Subacromial temperature profile during bipolar radiofrequency use in shoulder arthroscopy. Comparison of Coblation® vs. VAPR® - 29/11/17

Doi : 10.1016/j.otsr.2017.02.011 
V. Huynh , O. Barbier, X. Bajard, A. Bouchard, D. Ollat, G. Versier
 Service de chirurgie orthopédique et traumatologique, hôpital d’instruction des armées Bégin, 69, avenue de Paris, 94160 Saint-Mandé, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

The use of bipolar electrodes for arthroscopic procedures carries a theoretical ex vivo risk of inducing burn injuries. Few studies have measured the in vivo temperatures produced by bipolar electrodes during arthroscopy, and their results are conflicting. The objective of this study was to evaluate the temperature profile within the subacromial space during shoulder arthroscopy with two different electrode systems.

Hypothesis

The primary hypothesis was that the two electrode systems produced similar temperature variations and peak temperatures. The secondary hypothesis was that neither electrode system produced irrigation-fluid temperatures above the tissue-damage threshold.

Material and methods

A comparative, prospective, single-centre, single-surgeon, single-blind study was conducted to compare the Coblation® system (Smith&Nephew, Andover, MA, USA) and the VAPR® system (DePuy Synthes Mitek Sports Medicine, Raynham, MA, USA) in 13 patients undergoing shoulder arthroscopy. A temperature probe inserted into the subacromial space was used to record temperatures at 10-second intervals for 60seconds during continuous radiofrequency application.

Results

Mean baseline temperature was 21.4±0.7°C with VAPR® and 23.0±2.2°C with Coblation®. No significant between-group differences were found during the first 40seconds. The mean peak temperature reached after 60seconds was 25.0±1.9°C with VAPR® and 27.9±2.8°C with Coblation® (P<0.05).

Discussion

Few studies have compared the in vivo temperatures produced during arthroscopy by different electrode systems. In vivo studies have established that temperature increases can cause tissue damage, particularly to chondrocytes, and that the irrigation flow rate plays a key role in lowering the in vivo temperatures. Our study showed a significant difference between the two electrode systems after 50seconds of use, with lower temperatures with the VAPR®. Nevertheless, neither system increased the irrigation-fluid temperatures above the tissue-damage threshold. Both systems can be used safely, provided the manufacturer instructions are followed and the irrigation system is effective.

Level of evidence

II (prospective randomized trial).

Le texte complet de cet article est disponible en PDF.

Keywords : Temperature, Coblation, VAPR, Shoulder, Arthroscopy


Plan


© 2017  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 4

P. 489-491 - juin 2017 Retour au numéro
Article précédent Article précédent
  • Learning the skills needed to perform shoulder arthroscopy by simulation
  • P.-S. Marcheix, G. Vergnenegre, F. Dalmay, C. Mabit, J.-L. Charissoux
| Article suivant Article suivant
  • Changes of the bone structure after cap resurfacing arthroplasty of the humeral head
  • L.V. von Engelhardt, M. Hahn, T. Schulz, K. Peikenkamp, J. Jerosch

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.